Full Product Manual

NOTICE TO INSTALLER/CUSTOMER
PLEASE READ CAREFULLY BEFORE HOOK-UP!
1. The dwelling must have an adequate air supply and access to fresh air/oxygen in order to operate safely.
Propane fridges/freezers, like any other gas appliance, must have access to fresh air/oxygen. This unvented
appliance must not be used in an air-tight application.
2. This refrigerator must be installed by a licensed gas fitter.
3. The propane gas supply pressure regulator must be set at 11” water column.
4. The left side heat shield (facing front of the refrigerator) must be installed. The heat shield is shipped in the
refrigerator carton attached to the fridge.
5. The safety and ecient operation the proper clearances on all sides and top must be maintained. The
clearances are listed in the Owners Manual.
6. The proper and ecient operation the refrigerator must be level, both side to side and front to back (use
bubble type level).
7. The Combination Carbon Monoxide (CO) Alarm & Safety Shut-O must be installed and connected (CM
Models only) with the Alarm mounted as indicated in the Carbon Monoxide Alarm (Monitor) Installation Manual
located in the CO Monitor Box.
NOTE: It is illegal to operate this refrigerator in Canada without the Combination Carbon Monoxide
Alarm & Safety Shut-O installed, and will void the Canadian standards Association Certification. Non
compliance will void the Canadian certification and void household/cottage insurance coverage. This
refrigerator vents combustion products directly into the living space. The CO Alarming Device with Safety
Shut-O has been added to this refrigerator to guard against potentially high levels of Carbon Monoxide,
which can kill you. Once unsafe levels of CO are detected, an alarm will sound and the refrigerator will be shut
o.
WARNING: Actuation of this device indicates the presence of unsafe levels of carbon monoxide (CO) which
can KILL YOU. If alarm signal sounds:
a. Immediately move to fresh air - outdoors or by an open door or window. Check that all persons are accounted
for. Do not re-enter the premises or move away from the open door/window until the emergency services
responders have a,rived, the premises have been aired out, and your alarm remains in its normal condition;
b. Call emergency local service telephone number, fire department or 911.
c. The following symptoms may be related to CARBON MONOXIDE POISONING and should be discussed with
ALL members of the household:
Mild Exposure: Headaches, running nose, sore eyes, often described as “flu-like symptoms;
Medium Exposure: Dizziness, drowsiness, vomiting;
Extreme Exposure: Unconscious, brain damage, death.
d. Read the instructions for complete information on Alarms Signals.
8. Regular maintenance of the fridge critical to prevent unsafe levels of Carbon Monoxide.
Before lighting the refrigerator at any time, clean the flue tube as per the Owners Manual & make sure the
burner and areas around the burner are free from any lint, spider webs or any other debris. Please record your
appliance maintenance on the SERVICE RECORD label located at the back of your appliance.
WARNING - Test the Combination Carbon Monoxide & Safety Shut-O device operation after the refrigerator
has been in storage, before each start up, and at least once per week during use.