Full Product Manual

110V OPERATION
1. Ensure the electrical cord is plugged into a grounded outlet
2. Turn the selector switch G to AC position, AC power indicator F will illuminate
3. To start the refrigerator, turn the thermostat knob E to the maximum setting.
4. Adjust the thermostat knob to desired temperature setting after 8 hours of operation.
CONTROLS – See Fig. #5 for a description of controls
Shut Down” Procedure
1. Turn the selector knob G to the OFF position
OPEN
- AAA -
CLOSE
A
PUSH WHEN LIGHTING
OFF / ON
POWER ON
AC
GAS
OFF
C D
G
E
1 2
4
3
F
SM/CM/DV MODEL 6C/8C/10C/19C
LPG Operation
1. To start the refrigerator, turn the thermostat knob E to maximum setting.
2. Turn button G to Gas position, then push A button in and hold for the electronic igniter to light the burner,if no electronic ignition exists then repeatedly press A, continue to hold the D
button until you see the needle on the flame sensor C has moved from the white into the green area. The burner should now be "on", if not repeat the lighting instructions above. Once in
green zone for 15-30 seconds, release D button. If there is no click sound while depressing the A button the batteries need changing. If DV model DO NOT HOLD in D button before
pressing the A button or you could flood the burner box.
3. Adjust the thermostat knob to desired temperature setting after 4 to 8 hours of operation.
4. To change the batteries in the electronic ignition button to the left to expose the battery, remove AAA battery and replace with new one, replace the knob and turn the to the right to close.
110V Operation
1. Ensure the electrical cord is plugged into a grounded outlet.
2. Turn the selector switch G to AC position, AC power indicator F
will illuminate.
3. To start the refrigerator, turn the thermostat knob E to maximum
setting. Adjust the thermostat knob to desired temperature setting
after 4 to 8 hours of operation.
298.5 mm
63.5 mm
A B C D E F G
THERMOSTAT
The refrigerator cooling temperature is controlled by a thermostat that can be adjusted by turning knob E to
dierent settings to maintain the desired refrigerator temperature. It also incorporates a safety device which
automatically shuts o the supply of gas if the flame goes out. The electronic ignition discharges sparks
onto the burner when the appropriate button is pushed.
1. “MIN” Setting on the Gas Thermostat: In gas operation, the thermostat closes its main valve and
the burner runs continuously at the bypass rate or pilot flame. (Counter-clockwise turn). If left at the
minimum position for an extended period of time the fridge will defrost.
2. “MAX” Setting of the Thermostat: In gas operation, the thermostat allows the burner to remain on high
flame continuously. (Clockwise turn)
3. The thermostat can be adjusted between “Max” and “Min” (4 or 1) to obtain the desired fridge
temperature.
When the thermostat reaches the set temperature, it will cut the burner back to bypass operation other than
Max and Min setting.
The setting of the thermostat is critical and we recommend it be adjusted to maintain a dry frost on the
cooling fins (approx. 38° Fahrenheit or 3° Celsius). Adjust the thermostat knob closer to “Max” (clockwise)
when the outside temperature rises.
NOTE: When first turning the refrigerator on, move refrigerator controls to maximum, which is the
recommended initial setting. After 24 hours, adjust the controls as needed.
9