Installation Guide

10
IN-LINE FUSE
A 15A in-line fuse is provided with this freezer in order to protect the
wiring. For 12V/24V operation, use a 15A fuse. A standard automo-
bile fuse is recommended and the fuse should be wired to the posi-
tive (“+”) side of the system close to the positive battery terminal.
A 15A fuse is provided with this freezer.
OPERATING VOLTAGE FUSE
12 V / 24 V 15 A
DC POWER CONNECTION continued
ATTENTION
If a longer connection cable is necessary, the cable cross section
(or gauge) must be equal to or greater than the cable sizes recom-
mended on the following table. Be careful that the input voltage at
the appliance does not drop below the cut-out voltage of the com-
pressor.
CABLE SIZE 12V CABLE
LENGTH
24V CABLE
LENGTH
AREA AWG
mm
2
/inch Gauge m ft m ft
2.5 /
3
/
32
12 2.5 8 5 16
4 /
5
/
32
12 4 13 8 26
6 /
15
/
64
10 6 19.5 12 39
10 /
25
/
64
8 10 32.8 20 65.6
LOW VOLTAGE DISCONNECT
The compressor electronics includes a low voltage disconnect fea-
ture. If the input voltage to the appliance falls below 10.4V (in 12 V
mode) or 22.8V (in 24 V mode), the compressor will shut-o. Once
the voltage increases above 11.7V (in 12V mode) or 24.2V (in 24V
mode), the compressor will resume normal operation.
This feature is designed to protect the system battery from experi-
encing too low a depth of discharge.
12 V OPERATION 24 V OPERATION
SHUT-OFF 10.4 V 22.8 V
RESTART 11.7 V 24.2 V