Installation Guide

UNIQUE UGP20G
12
orifices included in the packaging). When using this on NG gas, conversion must be
made by a qualified NG installer before attempting to operate the range on that gas.
For correct operation, the pressure of natural gas supplied to the regulator should be
between 4” and 5” of water column. For LP gas, the pressure supplied must be
between 10” and 12” of water column.
When checking for correct operation of the regulator, the inlet pressure must be at
least 1” more than the operating -manifold- pressure as given above. The pressure
regulator located at the back of the range manifold must remain in the supply line
regardless of whether natural or LP gas is being used.
Regulator is only good for ½ psi (14” w.c.) so test pressure must not exceed ½” psi.
Shut off the main gas supply valve before removing the old range and leave it off
until the new hook-up has been completed. Don’t forget to relight the pilot on other
gas appliances when you turn the gas back on.
Because hard piping restricts movement of the range, the use of a CSA certified
flexible metal appliance connector is recommended unless local codes require a hard-
piped connection. Never reuse an old connector when installing a new range. If the
hard piping method is used, you must carefully align the pipe; the range cannot be
moved after the connection is made.
To prevent gas leaks, use pipe joint compound resistant to LP or NG gases
(depending on set up) on all male -external- pipe threads.
1. In an easily accessible location, install a service manual gas shut off valve. Be
sure everyone operating the range knows where and how to shut off the gas
supply to the range.
2. When all connections have been made, be sure all range controls are in the
off position and turn on the main gas supply valve. Check for gas leaks by
using a soap and water solution. If a gas leak is present, shut off gas
immediately, tighten all connections, and retest for leaks.
!
3. Any opening in the wall behind the appliance and in the floor under the
appliance shall be sealed.
After installation:
1. Check ignition of cooktop burners.
2. Check ignition of oven burner.
3. Check for gas leaks at all gas connections (using a gas detector, never a flame)