Installation Guide

17
U N I Q U E U G P 2 0 G
10. Remove all LPG orifices: place in the bag and store in a safe place.
11. Take the NG orifices provided and install them as shown below
See below for rating of orifice for each model
Smallest Medium x 2 Largest Oven
NG 0.8 mm 1.5 mm 1.28 mm 1.7 mm
12. Once all the orifices are installed, replace all burners and burner caps, then fire up
the burners to check the minimum flame height.
13. Minimum flame height should be approx. ¼” tall. There is a small adjustment
screw located on the valve itself. The lid and the front control panel must be
removed to accomplish this adjustment.
14. Turn the valve fully counter clockwise. Then proceed to adjust the adjustment
screw counter clockwise for a smaller flame and clockwise for a larger flame.
Adjustment: Minimum flame should be approx. ¼” tall
Orifice Location
Adjustment location is
inside the valve stem
Burner Orifice
Flame Height Adjustment
15. Temporarily replace the lid, burners, burner caps and grates and recheck the flame.
Once complete, reassemble the control panel and the lid.
16. Next, the oven orifice needs to be replaced.
17. Remove all racks, then the bottom pan by lifting up the back first to release the
front then pull pan out.