Installation Guide

14
Note: What you read on the converter cap or plunger is the type of gas for which the
regulator is set. If yours reads NAT, the regulator is set for natural gas. If yours reads LP,
the regulator is set for LP.
2. Top Pilots (Gas)
The top burner pilots can be adjusted by a screw located on the pilot filter attached
on the rear face of the manifold pipe. Adjust the pilot flame until there is only a
slight tip of yellow on the flame. Pilots are constant burning. DO NOT BLOW
OUT FLAME WITHOUT TURNING OFF PILOT ADJUSTMENT SCREW.
3. Top Burner Valves
Top burner valves have orifices that are dedicated to the type of fuel to be used. These
orifices are not adjustable. They must be changed completely to convert from one gas to
the other. DO NOT DISCARD THE UNUSED ORIFICES. They should be saved in
order to convert the range back to its original fuel.