WhenusingthisonLPGgas,conversionmustbemadebyaqualiedLPGinstall-
er before attempting to operate the range on that gas.
For correct operation, the pressure of natural gas supplied to the regulator should 
be between 4” and 5” of water column. For LP gas, the pressure supplied must be 
between 10” and 12” of water column.
When checking for correct operation of the regulator, the inlet pressure must be at 
least 1” more than the operating -manifold- pressure as given above. The pressure 
regulator located at the back of the range manifold must remain in the supply line 
regardless of whether natural or LP gas is being used.
Regulator is only good for psi (14” w.c.) so test pressure must not exceed 
1
/
2
” psi.
Shut off the main gas supply valve before removing the old range and leave it off 
until the new hook-up has been completed. 
Because hard piping restricts movement of the range, the use of a CSA/ETL cer-
tiedexiblemetalapplianceconnectorisrecommendedunlesslocalcodesre-
quire a hardpiped connection. Never reuse an old connector when installing a new 
range. If the hard piping method is used, you must carefully align the pipe; the 
range cannot be moved after the connection is made.
To prevent gas leaks, use pipe joint compound resistant to LP or NG gases (de-
pending on set up) on all male -external- pipe threads.
1. In an easily accessible location, install a service manual gas shut off valve. Be 
sure everyone operating the range knows where and how to shut off the gas 
supply to the range.
2. When all connections have been made, be sure all range controls are in the off 
position and turn on the main gas supply valve. Check for gas leaks by using a 
soap and water solution. If a gas leak is present, shut off gas immediately, tight-
en all connections, and retest for leaks.
3.Anyopeninginthewallbehindtheapplianceandintheoorundertheappli-
ance must be sealed.
After installation:
1. Check ignition of cooktop burners.
2. Check ignition of oven burner.
3. Check ignition of broiler burner.
4.Checkforgasleaksatallgasconnections(usingagasdetector,neveraame)
GAS CONNECTIONS (All Units)