To convert application and/or adjust from NG to LPG
The range is set for use with Natural Gas (NG). The factory setting is indicated on 
the serial plate. When set for Natural Gas operation, the pressure regulator will 
regulate the gas to 4 inches water column pressure. When set for Liquid Propane 
Gas (LPG) operation, the pressure regulator will regulate the pressure to 10 inches 
water column.
Natural Gas to Liquid Propane Gas Conversion
Theconversionkitmustbeinstalledbyqualiedserviceagency.
WARNING: Please ensure before beginning converting the appliance that the gas 
supply is shut off and the electrical connection is disconnected. Failure to do can 
result in injury or property damage.
GAS RANGE CONVERSION
“Thisconversionkitshallbeinstalledbyaqualiedserviceagencyin 
accordance with the manufacturer’s instructions and all applicable codes and require-
ments of the authority having jurisdiction. If the information in these instructions is not 
followedexactly,are,explosionorproductionofcarbonmonoxidemayresultinprop-
ertydamamge,personalinjuryorlossoflife.Thequaliedserviceagencyisresponsi-
ble for the proper installation of this kit. The installation is not proper and complete until 
theoperationoftheconvertedappliancesischeckedasspeciedinthemanufacturer’s
instructions supplied with the kit.”
Natural Gas Orifices
BTU 11,000 10,000 3,200 10,000 8,000 12,800
BURNER Auxiliary 
Burner
Semi-Rapid 
Burner
Triple Burner Rapid Burner Broil Burner Oven Burner
POSITION Front Right Rear Left Rear Right Front Left
ORIFICE 1.62 1.50 0.90 1.50 1.41 1.85
Liquid Propane Gas Orifices
BTU 10,500 9,000 3,200 9,000 9,000 12,800
BURNER Auxiliary 
Burner
Semi-Rapid 
Burner
Triple Burner Rapid Burner Broil Burner Oven Burner
POSITION Front Right Rear Left Rear Right Front Left
ORIFICE 1.00 0.93 0.57 0.93 0.93 1.07