Installation Guide

23
24” MODEL
GAS RANGE CONVERSION
ATTENTION: YOUR PRODUCT IS PRE-INSTALLED WITH NATURAL GAS
INJECTORS AND REGULATOR.
IF YOU ARE USING LP GAS, PLEASE REFER TO THE INSTALLATION
INSTRUCTIONS INCLUDED WITH THE CONVERSION KIT.
Convertible Pressure Regulator
TherangeisshippedtooperateonNG.LPGorices
and a special screwdriver for adjusting the minimum
ameareshippedwiththeunitinaseparateenvelope
with the manual. The inlet pressure of the gas supply
shall be in accordance with the nominal inlet pressure
of the regulator used on the range or 1/2 psig maxi-
mum. The range should be tested by pressurizing the
regulator with an inlet pressure at least 1 inch water
columnabovethemanufacturer’sspeciedmanifold
pressure shown on the serial plate.
2. Screwdriver
1.Orices
Parts List:
1. CAUTION: Before proceeding with
the conversion, shut off the gas
supply to the appliance prior to dis-
connecting the electrical power
2. Locate convertible regulator at the
back of the range, left side facing
back of appliance. Unscrew cap to
locate pin.
3. On the side of the pin you will see the respective marking for LPG and NG.
4.UnscrewpinandipittotheLPGposition(arrowfacingcapindicatingcor-
rect setting)
5. Replace the cap back on the regulator
Top Burner Ori ces
6. Remove the grates, burners and burn-
er caps from the range to
accesstheorices.