Installation Guide

11
12 V OPERATION 24 V OPERATION
SHUT-OFF 10.4 V 22.8 V
RESTART 11.7 V 23.4 V
Your Unique freezer, like any battery-powered refrigerating appli-
ance, requires dierent care than appliances plugged into an elec-
tric utility. Prudent operation is the key to extended service.
STARTING THE FREEZER
After the freezer has been properly connected to the 12 or 24 V DC
power source or the AC/DC adaptor (sold separately), the compres-
sor will automatically turn on and the cabinet will begin cooling. Al-
low the cabinet to cool for at least 4 hours prior to adding food.
OPERATION
TEMPERATURE CONTROL
The temperature within the freezer compartments is controlled by
the panel situated on the outside of the appliance.
1) Set: Press the “set” button one time, then press the “up” or “down”
button to control the temperature that you want, the temperature
will then set and after 3 seconds show you the temperature in the
unit again.
2) Power: Press and hold the “power” button for 3 seconds to turn
the unit o. Press and hold the “power” button for 1 second and the
unit will power up, the compressor will restart several minutes later.
3) UVP Voltage: High - 26V, Med - 25V, Low - 23V. Recommended
voltage setting is “Low”
*NOTE: Temperature controller has a + or - , 0.5 range. The freezer
will run a few degrees colder at high elevations.
Max (Quick freezing
mode) is not recom-
mended for solar and
battery use)
Eco (Power saving
mode) takes longer
to cool down and
uses less electricity
UVP: Voltage setting
mode - H (HIgh 26V)
M (Medium 25V) L
(Low 23V)
Temperature Control
Power
Temperature Set
Temperature & Error
Code Display
Voltage & Power
Display