45L / 1.
TABLE OF CONTENTS 03 04 05 06 06 06 06 07 09 11 11 12 12 13 14 15 16 17 18 20 20 21 21 Installation and operation of your Unique portable AC/DC fridge/freezer Defrosting the cabinet UGP-45L1 W Portable fridge/freezer: features Power requirements AC power connection DC power connection Emergency overide Replacing the fuse Operation Error codes Bluetooth APP Connecting to a battery Using solar panels Using portable generators Tips and suggestions Technical specifications Troubleshooting Wiring diagram Parts
INSTALLATION AND OPERATION OF YOUR UNIQUE PORTABLE AC/DC FRIDGE/FREEZER IMPORTANT: After transit where the fridge/freezer is on its side or back, ensure fridge/freezer is in a level, upright position for 3-4 hours to allow compressor fluids to redistribute evenly before use. It is important that your fridge/ freezer is installed and operated in accordance with the manufacturer’s instructions to guarantee the performance, efficiency and operation.
INSTALLATION AND OPERATION OF YOUR UNIQUE PORTABLE AC/DC FRIDGE/FREEZER continued IMPORTANT This fridge/freezer is not intended for use by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are under supervision or instruction concerning the use of the fridge/freezer by a person responsible for their safety. • This is not a toy. Do not allow children to play with or within the fridge/freezer.
UGP-45L PORTABLE FRIDGE/FREEZER FEATURES Stainless steel lid latches Internal LED light Powder coated steel exterior Emergency overide Sturdy side handles Protective corners 1 x Drain plugs 2 x Storage Baskets Digital control panel 1 x USB 2.
POWER REQUIREMENTS The Unique UGP-45L1 W portable fridge/freezers are designed to operate on AC and DC voltage inputs. AC input Voltage is required to be 110V AC at 50 - 60 Hz DC input Voltage is required to be 12 or 24 DC +/- 10% AC/DC Convertor is 12V AC POWER CONNECTION The Unique UGP-45L1 W portable fridge/freezers are supplied with an approved 2 pin AC power cord. It is recommended that this cord is not lengthened as this may result in a voltage drop and reduced performance.
If the Emergency Switch is turned on. The control panel will only show the temperature and voltage, you will not be able to set the temperature or voltage. NORMAL USE EMERGENCY OVERIDE DC 12V / 24V 12 / 24V based on input 12 / 24V base sur l’entree IT IS NOT FOR EVERYDAY USE - ONLY FOR EMERGENCIES REPLACING THE FUSE The Unique UGP-45L1 W portable fridge/freezers are supplied with 2 additional replacement 10A fuses for the adaptor. These can be found in a plastic bag attached to the cord.
REPLACING THE FUSE continued IN-LINE FUSE A 15A in-line fuse is provided with this fridge in order to protect the wiring. For 12V/24V operation, use a 15A fuse. A standard automobile fuse is recommended - A 15A fuse is provided with this fridge/ freezer. Remove screws from the feet and grate to access 15A fuse and compressor compartment.
OPERATION CO M P R E SSOR R UN SET L E F T BI N H I GH Q U ICK MED NOR M LOW US B 2.1A ECO BAT T E RY P R OT E C T I ON ON/OF F CO OLIN G SPEED BLUETOOTH APP Please refer to your Bluetooth APP Instruction manual for details COMPARTMENT CONTROL Compartment temperature control enables either a fridge or freezer option. COMPRESSOR RUN SET Temperature setting range: -22°C ~ +10°C, -8°F ~ 50°F LEFT BI N HI GH QUICK Plug in the DC or AC power cable.
CO M P R E SS O R RUN S ET OPERATION LEFT BIN H ICO G HM P R E SS O R RUN QUICK Battery Protection: press and hold the voltage setting button for 3 seconds to adjust the Low, Middle , High voltage. We recommend the Middle voltage for operation. MED CO M P R E SS O R RUN SET LOW U S B 2 .1 A SET LEFT BIN L E F T BI N B AT T E RY P R OT E C T I O N HIGH O N /O F F MED QUICK MED NORM LOW ECO U S B 2.1 A BATTE RY P R OTE C TI O N O N /O F F NORM LOW U S B 2 .
ERROR CODE Error Code Error type can be read out on the control display Thermostat failure Err 7 (If the NTC thermistor is shortcircuit or has no connection). Err 6 Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient tempreature is high, the electronic unit will run too hot). Err 5 Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm).
CONNECTING TO A BATTERY Your DC fridge/freezer can run off a single 12V or 24V power supply. When connecting to a 12V battery, ensure that the supplied connection wires are used. Connect the positive wire (red) to the positive terminal on the battery and the negative wire (black) to the negative terminal on the battery. Please ensure that your deep cycle battery is fully charged and is properly connected to the Unique Portable Solar Panel system (UGP-100WSPB and/or UGP-120WSP) or a power generator.
USING PORTABLE GENERATORS It is important that the correct generator is used with your UGP45L1 W portable fridge/freezer. An incorrect generator may result in reduced performance or damage to your appliance which may void your appliance’s warranty. If connecting directly to an AC generator, ensure that only a digital or inverter type generator is used. These provide a more reliable and constant 110V AC output and are specifically designed to power electronic and other power sensitive appliances.
TIPS AND SUGGESTIONS • Fresh and frozen foods should not be stored together. Frozen surfaces can cause frost damage on fresh foods which can then lead to spoilage. It is best to put an insulating layer between these goods or to organize them into separate compartments. • When the appliance is being set at 0˚C / 32˚F or lower, do not store glass bottles or liquids such as beer, wine, juices or soft drinks in the unit as they may freeze and shatter.
TECHNICAL SPECIFICATIONS MODEL UGP-45L1 W GROSS CAPACITY 45 L / 1.6 cubic feet ZONE Single SETTING TEMPERATURE -22˚C/-7.6˚F to +10˚C/50˚F (in ambient temperature between +1˚C/34˚F to +43˚C/109˚F) POWER CONSUMPTION 37 W (power consumption varies based on temp. setting) AVERAGE RUN CURRENT 3.1 amps on 12V DC REFRIGERANT R134a / 65g INSULATION MATERIAL C5h10/C-Pentane INSULATION THICKNESS Wall: 50mm / Lid: 55mm WEIGHT (kg, approx.) 21.5 kg / 47.4 lbs EXTERNAL DIMENSION (HxWxD) 25.4” x 14.
TROUBLESHOOTING PROBLEM CAUSE SOLUTION THE COMPRESSOR DOES NOT RUN The polarity of the positive and the negative have been reversed. Switch off the power and check the polarity of the connections. Check your in-line fuse within the cigarette lighter plug. The voltage is insufficient or interrupted. Switch off power. Check connections and then fuses. The voltage is insufficient or interrupted. Switch off power. Check connections and then restart.
UGP-45L1 W Wiring Diagram Label UGP-45L1 W WIRING DIAGRAM UGP-45L1 W Wiring Diagram UGP-45L1 W Schéma de Câblage DC 12/24V COMPRESSOR UNIT UNITE DE COMPRESSEUR TEMP.
UGP-45L1 W PARTS DIAGRAM AND LIST * Please visit our website www.uniqueoffgrid.
PARTS DIAGRAM AND LIST continued ITEM # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 PART # UGP-BCD45-001 UGP-BCD456580120-002 UGP-BCD456580120-003 UGP-BCD456580120-004 UGP-BCD45-004 UGP-BCD45-005 UGP-BCD456580120-007 UGP-BCD456580120-002 UGP-BCD456580120-009 UGP-BCD456580120-010 UGP-BCD456580120-011 UGP-BCD45-012 UGP-BCD45-013 UGP-BCD45-014 UGP-BCD456580120-015 UGP-BCD45-016 UGP-BCD456580120-017 UGP-BCD45-018 UGP-BCD456580120-019 UGP-BCD456580120-020 UGP
APPLIANCE INFORMATION (manual copy - keep with your records) To make care and servicing of your fridge/freezer easy and efficient, please record the following information for future reference: Model: Serial Number: Purchased From: Date Purchased: PRODUCT REGISTRATION Please visit our website at http://uniqueoffgrid.com/product-registration/ to register your product.
CONTACT US For questions related to the operation, safety or the purchase of your fridge/freezer, please contact your dealer for more information. For general information, contact our customer service department: • Toll-free: 1-877-427-2266 or 1-905-827-6154 (available during regular business hours, 8:30 am to 4:30 pm, EST. • Email: info@UniqueOffGrid.com Please visit our website for more quality off-grid products: www.uniqueoffgrid.com Unique Gas Products Ltd.
© 2019 Unique Gas Products Ltd., 2245 Wyecroft Road, Oakville, Ontario, Canada, L6L 5L7 www.uniqueoffgrid.