Owners Manual

22
GAS RANGE CONVERSION (continued)
Convertible Pressure Regulator
The range is shipped to operate on LPG. NG orices and a special screwdriver for
adjusting the minimum ame are shipped with the unit in a separate envelope with the
manual. The inlet pressure of the gas supply shall be in accordance with the nominal
inlet pressure of the regulator used on the range or 1/2 psig maximum.
The range should be tested by pressurizing the regulator with an inlet pressure at least
1 inch water column above the manufacturer’s specied manifold pressure shown on
the serial plate.
1. CAUTION: Before proceeding with the conversion, shut off the gas supply to the
appliance prior to disconnecting the electrical power (if applicable).
2. Locate convertible regulator at the back of
the range, left side facing appliance. Remove
cap and pop out the pin that’s attached
3. On the side you will see the pin position for
use with LPG
4. Unscrew pin and ip it to the NG position
long end outwards, spring on inside.
5. Below is an example of additional positions
depending on regulator type installed.
LPG NG
1.5'
0
0
1.5'
14000 BTU 0.53mm +0.77 (LPG)
13000 BTU 0.68mm +1.28 (NG)
13500 BTU 1.12mm (LPG)
13000 BTU 1.9mm (NG)
3200 BTU 0.57mm (LPG)
3200 BTU 0.90mm (NG)
9000 BTU 0.93mm (LPG)
10000 BTU 1.50mm (NG)
9000 BTU 0.93mm (LPG)
10000 BTU 1.50mm (NG)