Owners Manual
23
6. Replace the cap back on the regulator
7. Next you will remove the grates, burners and burner
caps from the range to access the orices.
8. You will need a 7 mm wrench to remove the orices.
Each orice can be accessed easily - the larger
burner orice is located on the burner wall.
9. Remove all LPG orices: place in the bag and store in
a safe place.
10. Take the NG orices provided and install them as shown below
See below for rating of orice for each model
Smallest Medium x 2
Largest
Oven
LPG 0.90 mm 0.93 mm 0.53 mm 0.77 mm x2 1.12 mm
NG
0.90 mm 1.50 mm 0.68 mm 1.28 mm x2 1.9 mm
11. Once all the orices are installed, replace all burners and burner caps, then re up
the burners to check the minimum ame height.
12. Minimum ame height should be approx. 1/4” tall. There is a small adjustment screw
located on the valve itself. The lid and the front control panel must be removed to
accomplish this adjustment.
13. Turn the valve fully counter clockwise. Then proceed to adjust the adjustment screw
counter clockwise for a smaller ame and clockwise for a larger ame. Adjustment:
Minimum ame should be approx. 1/4” tall.
14. Temporarily replace the lid, burners, burner caps and grates and recheck the ame.
Once complete, reassemble the control panel and the
lid.
15. Next, the oven orice needs to be replaced.
16. Remove all racks, then the bottom pan by lifting up the
back rst to release the front then pull pan out.
17. Locate the burner tube and locate the retaining screw
at the front of the tube. Once this screw has been
removed, lift up the burner and pull away slightly to the
right to expose the oven orice.
18. With a 7 mm wrench or pliers remove the orice and replace with NG orice.
GAS RANGE CONVERSION (continued)
BURNER ORIFICE
FLAME HEIGHT ADJUSTMENT
Adjustment location is
inside the valve stem
Adjustment location is inside the
valve stem
ORIFICE
LOCATION