column above recommended pressure, 12” for propane gas, and 5” water column for
natural gas. When properly adjusted the manifold water column pressure is 11” for LP/
propane gas or 4” for natural gas.
NOTE: There is no adjustment for the pilot ame, you must use the NG pilot orice
included in the conversion kit and this will ensure the pilot ame is the correct size
(see image).
NOTE: Once the unit has been converted ll out the included sticker and place it on
the back of the range, beside the rating plate (see image).
Once you have completed the conversion,
check the operations of ignition making
sure each of the 4 burners, pilot ame and
oven burner ame are functioning correctly.
Please refer to pages 28 through 30 – Operation of
Range.
High Altitude Applications above 2,000 feet: At
elevations above 2,000 feet, the range must be
derated 4% for each 1,000 foot above sea level.
It is the installers responsibility to see that the
ranges input rate is adjusted properly.
CHECKING FOR MANIFOLD GAS PRESSURE
THERMOCOUPLE
IGNITER
OVEN PILOT
PILOT ORIFICE