User Manual

18
The appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures
in excess of
1
/
2
psig.
The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1
/
2
psig.
• Gas line shut-off valve
To reduce the possibility of gas leaks, apply
Teontapeorathreadcompoundapproved
for use with LP or Natural gases to all threaded
connections.
•Useaexibleapplianceconnectortoconnect
your gas supply to the appliance. A 3 foot length
is recommended for ease of installation but
other lengths are acceptable. Never use an old
connector when installing a new range.
• Check for leaks using a leak detector or soapy
water with a recommended ratio of 75% water,
25% dish washing soap.
Installation
It is the responsibility of the installer to make
certain that the range is properly adjusted at
the time of installation. Situations caused by
improper adjustments or improper installation
are not covered under the warranty. Any expenses incurred due to such situations
will not be paid by the manufacturer of the appliance.
Connecting gas to range
This range is designed to operate at a pressure of 4” of water column on natural
gas (NG) or 10” of water column on propane gas (LPG).
Make sure you are supplying your range with the type of gas for which it is
designed. This range comes equipped from the factory equipped for use
with NG (natural gas). This range is convertible for use on propane (LPG) also
(propaneoricesincludedinthepackaging).