To convert application and/or adjust from NG to LPG
The range is set for use with Natural Gas (NG). The factory setting is indicated on
the serial plate. When set for Natural Gas operation, the pressure regulator will
regulate the gas to 4 inches water column pressure. When set for Liquid Propane
Gas (LPG) operation, the pressure regulator will regulate the pressure to 10 inches
water column.
Natural Gas to Liquid Propane Gas Conversion
Theconversionkitmustbeinstalledbyqualiedserviceagency.
WARNING: Please ensure before beginning converting the appliance that the gas
supply is shut off and the electrical connection is disconnected. Failure to do can
result in injury or property damage.
GAS RANGE CONVERSION
“Thisconversionkitshallbeinstalledbyaqualiedserviceagencyin
accordance with the manufacturer’s instructions and all applicable codes and require-
ments of the authority having jurisdiction. If the information in these instructions is not
followedexactly,are,explosionorproductionofcarbonmonoxidemayresultinprop-
ertydamage,personalinjuryorlossoflife.Thequaliedserviceagencyisresponsible
for the proper installation of this kit. The installation is not proper and complete until the
operationoftheconvertedappliancesischeckedasspeciedinthemanufacturer’s
instructions supplied with the kit.”
Natural Gas Orifices
BTU 11,000 10,000 3,200 10,000 8,000 12,800
BURNER Auxiliary
Burner
Semi-Rapid
Burner
Triple Burner Rapid Burner Broil Burner Oven Burner
POSITION Front Right Rear Left Rear Right Front Left
ORIFICE 1.62 1.50 0.90 1.50 1.41 1.85
Liquid Propane Gas Orifices
BTU 10,500 9,000 3,200 9,000 9,000 12,800
BURNER Auxiliary
Burner
Semi-Rapid
Burner
Triple Burner Rapid Burner Broil Burner Oven Burner
POSITION Front Right Rear Left Rear Right Front Left
ORIFICE 1.00 0.93 0.57 0.93 0.93 1.07
24” Model