ADJUSTING THE OVEN BURNER FLAME
1) Light the burner by turning the thermostat to the 500ºF position,
2) Remove the knob by pulling straight out.
3) Remove the two (2) Phillips head screws that secure the bezel to the control
panel.
4) Carefully lift the bezel away from the control panel to allow access to the access
hole below the valve stem. (see illustration).
5)Inserttheatheadscrewdriver(2.5mmx75mm)intothescrewholeandturn
the bypass screw clockwise to adjust the
ame.
DO NOT OVERTIGHTEN.
6) Mount the knob to the valve stem.
7) Allow the oven to heat up for approximately 10 minutes then rotate the knob to
the 300ºF position to operate the thermostat by-pass. Slowly screw the by-pass
screwuntilyouobtainaameofapproximately3–4mminheight.
8) Carefully replace the bezel and knob ensuring not to damage wires.
OVEN VALVE
Theovencontrolhasaamesafetydevicebuiltintothebodyofthethermostat.
Presenceofagasignitionsource(pilot)isveriedbyaamesafetyprobe.This
amesafetyprobeactuatestheinternalsafetydevicetoallowgasintotheoven
burner when the oven is turned on. If there is a loss of gas ignition during operation,
theamesafetydevicewillcloseoffgasowtotheovenburnerandpilot.
Theovenburneroriceislocatedonabrassinjectorstudattherearoftheoven
undertheovenoor.Thisoriceisdedicatedtothegasforwhichtheovenistobe
used.Theoriceisnotadjustable.Itmustbechangedcompletelytoconvertfrom
one gas to the other. DO NOT DISCARD THE UNUSED ORIFICE. It should be
saved in order to convert the range back to its original fuel
ADJUSTING THE TOP BURNER AND OVEN FLAME
(continued)