TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE POSSIBLE FIX
Surface burners
do not light.
Surface control has not been com-
pletely turned to the ON position.
Push in and turn control to the ON position
until burner ignites, then turn control to de-
siredamesetting.
Burner ports are clogged. Use a small gauge wire or needle to open
ports.
Burners not positioned properly. Verify that the burners are positioned prop-
erlyontheoricehoodsandtheburnersare
sittingatontheburnersupportwithtabs
engaged in slots.
Range not set for appropriate gas
input.
See range conversion section of installation
manual.
Burners won’t light due to power
failure.
Light burners manually.
Range power cord is disconnected
from the outlet.
Be sure power cord is plugged into grounded
outlet.
Flame burns half-
way round.
Burner ports are clogged. Use a small gauge wire or needle to open
ports.
Moisture is present after cleaning. Lightlyfantheameandallowburnertooper-
ateuntilameisfull.ORdryburnersthor-
oughly following instructions in range “Clean-
ing” section.
Range is not set for appropriate gas
input.
See range conversion section of installation
manual.
Flame is orange.
Dust particles in main line. Allow burner to operate for a few minutes until
ameturnsblue.
Range is not set for appropriate gas
input.
See range conversion section of installation
manual.
Oven light does
not work.
Burned out or loose bulb Tighten or replace oven light bulb.
Oven or broiler
does not heat.
Range is not set for appropriate gas
input.
See range conversion section of installation
manual
Temperature control not set properly. Make sure temperature control is set at de-
sired temperature.
Burners will not light due to power
failure.
Light burners manually.
House fuse has blown or circuit
breaker has tripped.
Check/reset circuit breaker and/or replace
fuse. Do not increase fuse capacity. If the
problem is a circuit overload, have it corrected
byaqualiedelectrician.
Range cord is disconnected from
outlet.
Be sure the power cord is plugged into a
grounded outlet.