Unit installation

Unitary Products Group
ACCESSORY KIT INSTALLATION INSTRUCTIONS
1NP0580 - PROPANE CONVERSION ACCESSORY
TWO- STAGE INDUCED COMBUSTION FURNACES
MODELS: PT9 / FL9T / FC9T / GM9T / PV9 / FL9V / FC9V / GM9V / XYF9S / XYF9V
PT8 / FL8T / FC8T / GM8T / PV8 / FL8V / FC8V / GM8V / XYF8S / XYF8V
67404 / 035-20507-001 Rev. D (0205)
GENERAL
This kit is intended for the conversion of new equipment only,
from natural gas to propane gas operation.
All unit installations above 2,000 ft. must be field derated as
required by the National Fuel Gas Code, ANSI Z223.1 (latest
edition), or in Canada, CAN/CGA B149.1 or .2 and all other
applicable local codes and utility requirements.
This instruction covers the conversion of this unit when it is
equipped with a White- Rodgers gas valve. The installation
instruction supplied with the unit is to be used for all other
aspects of the installation.
FURNACE CONVERSION
1. Remove the upper access door. On 90+ AFUE units,
remove the burner box cover.
2. Carefully remove the wires from the gas valve and note
their location so they may be properly replaced. Remove
the screws that hold the manifold to the manifold bracket
and slide the manifold off the burners. On 90+ AFUE
units, the manifold is retained by two screws at the bot-
tom and hooks in at the top of the burner box.
This conversion kit is to be installed by a qualified service agency in accordance with the manufacturer's instructions and
all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not fol-
lowed exactly, a fire, an explosion or production of carbon monoxide may result causing property damage, personal injury
or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper
and complete until the operation of the converted appliance is checked as specified in the manufacturer's instructions sup-
plied with the kit.
The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.
Installation must be made in accordance with the National Fuel Gas Code, ANSI Z223.1-latest edition, unless superseded
by local codes. For Canadian installations, the conversion shall be carried out in accordance with the requirements of the
Provincial authorities having jurisdiction and in accordance with the CAN1-B149.1 and .2 installation codes. The manufac-
turer accepts no responsibility for malfunctions due to improper conversions.
Lo-NOx furnaces requiring propane (LP) gas must have the NOx screens removed prior to operation. Failure to do so may
result in operational problems and/or reduced heat exchanger life. Follow the instructions below for removal of the NOx
screens.
An overpressure protection device, such as a pres-
sure regulator, which conforms to the National Fuel
Gas code, ANSI Z223.1 (U.S.) or CAN- B149.1 or .2
(Canada) and acts to limit the downstream pressure
to value that does not exceed 0.5 PSI (14" w.c.),
must be installed in the gas piping system upstream
of the furnace. Failure to do so may result in a fire or
explosion or cause damage to the furnace or some
of its components.
CONTENTS OF KIT
DESCRIPTION PART NUMBER QTY
Propane Conversion Label 035-11635-000 1
Gas Line Pressure Switch 024-27688-XXX 1
Tapped Gas Pipe Nipple 029-22152-000 1
Main Burner Orifices 029-20423-056 6
Wire Harness 80% (1/4” Terminals) 373-20975-001 1
Wire Harness 90% (1/4” Terminals) 373-20976-001 1
Installation Instructions 035-20507-001 1
Valve Spring Kit 025-38943-000 1
The gas supply shall be shut off prior to disconnect-
ing the electrical power, before proceeding with the
conversion.