Unitech HT580L Operation Guide Version 1.
Overview ............................................................................................................................................................ 3 1. SETTING .............................................................................................................. 4 1.1. DATE & TIME .............................................................................................................................................. 4 1.2. Device...........................................
Overview HT580L operation guide will cover more detail on F/W setting and software development tool APG580 (Application Generation for HT580L) After power on HT580LL, it will show main menu as below HT580L V1.15 1. SETTING 2. FORMCACHING 3. RUN APG580 There are 3 options – Setting , Formaching and Run APG580.
1. Setting Setting menu do 2 major functions – User mode setting and Supervisor setting. In HT580L User Guide, it already explains user mode operation. This document will also repeat it again from below section. Note : Due to no barcode scanning requirement on Setting menu, SCAN key will also be treated as ENTER key during Setting operation.
1.2. Device Use MENU key to move cursor to one of item and then press ENTER (or SCAN key) or directly press “1” ~ “3” to select target item: 1. BACKLIGHT 2. SCANNER 3. AUTORUN 4. MEMORY 1.2.1. BACKLIGHT HT580L’s backlight can be automatically on after key pressed and it will automatically off after predefined period time if there is no more key pressed. Timeout period will be reset if any key is pressed. In HT580L, timeout period can be set to 10/20/30 or 60 seconds.
1.2.3. AUTORUN AUTORUN is defined to automatically run pre-define FORMCACHING or APG580 program after power on. Or setup HT580L to back to previous running point before power off. There are below 4 options for choice. Formcaching Always run Formcaching from beginning after power on HT580L APG580 Always run APG580(EasyJob) from beginning after power on HT580L RESUME Back to previous running point before power off. This option is default setting. OFF Always warm-start after power on.
Unitech Part Number: 400412 7
FormCaching Specification DATA FIELD DEFINITION: maximum field number=8 Category Range Description 3. FIELD PROMPT MIN/MAX Field LENGTH Field type 4. DEVICE TYPE 1. 2. Max.16 characters 1-48 1.NUMERIC 2.ALPHANUM 1.KEY ONLY 2.SCAN ONLY 3.BOTH DATA RECORD DEFINITION Category Range 5. Between Field 1.Append Screen 2.Clear Screen 6. FIELD DELIMITER 1. , 2. ; 3.SPACE 4.TAB 5. FIXED LENGTH 7. RECORD DELIMITER 8. DATE STAMP FIELD 9. TIME STAMP FIELD 10. Trasn. Mode 11. FIELD DELAY 1.CR 2.
HT580L FormCaching Defaults The HT580L enables FormCaching by default, the following settings also apply: DATA FIELD DEFINITION: field number=2 Category Setting Field #1 FIELD PROMPT ITEM: DATA LENGTH 20 DATA TYPE ALPHANUM DEVICE TYPE BOTH Field #2 FIELD PROMPT QTY: DATA LENGTH 8 DATA TYPE NUMERIC DEVICE TYPE KEY ONLY DATA RECORD DEFINITION Category Setting FIELD DELIMITER , RECORD FELIMITER CR DATE STAMP FIELD NONE TIME STAMP FIELD NONE FIELD DELAY 1 Unitech Part Number: 400412 9
1.3.1. BAR This option is use to configure individual symbologies for each barcode. After enter configuration menu, the LCD will display the BARCODE Setup as shown below. < BARCODE SETUP> CODE 39 ON Press [MENU] key to toggle between settings. Press [SCAN] or [ENTER] key to set.
UPC-E CODE 93 Code 128 TELPEN UK PLESSEY Leading digit Check Digit decoding UPC-E0 UPC-E1 EXPEND TO UPCA Leading digit Check Digit decoding decoding EAN128 EAN128 CODE ID EAN128 FUNC CH SEND/NOT SEND SEND/NOT SEND ON/OFF ON/OFF ON/OFF ON/OFF SEND SEND ON ON ON OFF SEND/NOT SEND SEND/NOT SEND ON/OFF ON/OFF ON/OFF ON/OFF NOT SEND/SEND decoding decoding Check Digit ON/OFF ON/OFF SEND/NOT SEND SEND SEND OFF ON ON OFF NOT SEND ON OFF SEND 1.3.2.
1.3.4. DIAG - Diagnostics The HT580L has a built-in diagnostics program to test the terminal's hardware. The test routines are data destructive. Therefore, before running the diagnostic program, make sure you back up the data in the HT580L. Note : When a H/W or S/W service has been made on the PT630, such as maintenance, repair or upgrade, it is strongly recommended to run the diagnostic program. 1. VER 3. LCD 5. PWR 7. RTC 1. VER 2. SCAN 4. COMM 6.KEY 8.MEM At the Supervisor Mode menu: 1. Press 7 (7.
2. Communication 2.1. USB communication To connect HT580L to PC via USB, you need to install USB driver which will redirect data to virtual COM port. You can get USB driver from HT580L CD. Window OS will prompt new device dialog box when PC is the first time to be connected to HT580L via USB. Please re-direct driver folder to Unitech’s USB driver folder and then follow its prompting to install driver.
4. Then it will search all of Bluetooth device within BT converge area and then list them down on the screen. You can find all of HT580Ls will be displayed as “UNITECH”. Then you can click “Next” button 5. Then it will prompt user to enter PIN code, HT580L’s default PIN (Pass key) is “0580”, then you can find this HT580L is already on your Bluetooth list. Then click right mouse button to connect it. 6. You can also check the correct PORT number from “Detail” PS.
2.3. Communication program In Easy Job, it also bundle one communication program named “MultiEj”. You can directly run it from HT580L EasyJob Or it from HT580L Easy Job and then then select Tool Communication as below diagram Then it will launch MultiEj program as below screen, You can directly 1. drag and drop files from PC folder to HT580L directory to execute download function 2. drag and drop files from HT580L directory to PC folder to execute upload function 3.
Before using MultiEj to do communication, you should setup correct port number and communication parameter by chick Options icon on menu bar. Then click “NEW” button to select a new COM port, then configure its proper communication parameter and click OK button to finish setting. Then you can select proper port from Connection List Box After select proper COM port, you will find icons of Date/Time , WarmStart and ColdStart changed from grey to color icon.
2.4. Modem communication For HT580L, Unitech provide modem cradle to enable modem communication function between PC and HT580L. So, user must connect phone line to cradle and HT580L still connect to cradle with RS232 interface. There are 2 ways to do connection. 1. Calling from PC 2. Calling from Terminal Call from PC To call modem from PC, HT580L’s modem cradle should be set to automatically pick up external call.
Unitech Part Number: 400412 18
3. Technical Specification Model HT580L Dimensions 123mm x 55mm x 25mm Weight 150g Drop Specification 1.2M free drop to concrete floor Display 128 x 64 pixel; 16x8 characters or 12x4 characters Battery One 3.
3.1. Pin Assignment The HT580L communicate via the RS232 communication port located on the bottom of the unit. You can connect the unit via the communication cable to PC RS232 jack for data transfer or connect through cradle for communication.
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.