UHF RFID Reader Module - RM100 - Quick Start Guide Version 1.
Introducing the RM100 UHF RFID Reader Module Unitech’s RM100 is a high-performance UHF RFID reader module based on the Impinj R2000 chip. It is compliant with EPC C1 Gen2 / ISO 18000-6C. RM100 has one (Ipex) antenna connector. It also supports dense reader mode (DRM), anticollision, and Listen-Before-Talk (LBT) features. RM100 has a long operating distance of up to 9 meters when its adjustable TX power is set to 33 dBm with a 4 dBi antenna. RM100 is small (55 mmx 35 mm x 4.
Specifications Protocol RFID EPCglobal Gen 2 (ISO 18000-6C), DRM Architecture RFID ASIC IMPINJ R2000 Processor ATMEL AT91SAM7S-256 Power Voltage 5V VDC Interface Connector 20-pin (HRS-DF12 SMT connector) UART Baud rates: 9,600 to 460,800 bps, Logic levels: 3.3 / 5 V USB USB 2.0 Full Speed (12 Mbps) GPIO 2 GPIO pins, Logic levels: 3.3 / 5 V API Interface Impinj RF Antenna Connector 1 Ipex connector TX power Adjustable from 10 dBm to 33 dBm @ +/-1.
Package Content Check the package before connecting and operating the RM100. If one or more items in this package are lost, contact your local dealer. RM100 UHF RFID Reader Module Power Adaptor Interface board USB Cable Antenna RFID Tag Note: 1. Length of antenna cable 60+/-2mm 2. Antenna cable is sealed on antenna board and can not be removed. 3 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
Tour of the RM100 UHF RFID Reader Module This section describes the main components and features of the interface board. Power Inlet Micro USB Port UART Port GPIO Port Installing the IndyTool First of all, install the IndyTool before connecting the interface board to a PC. It is possible for multiple versions of IndyTool to co-exist on a single system, so long as a unique install path is used for each, such as the default installation directory. Installation Procedure 1.
Connecting the RM100 to a PC Before operating the Indy tool software for development of the RFID device, follow the steps made below to connect the RM100 to a PC. 1. Install the Indy tool on your PC. 2. Mount the UHF RFID Module onto the interface board. 3. Connect the interface board to a PC by using a micro USB cable. 5 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
4. Insert the power connector into the power inlet on the interface board, and then plug the power adapter into an electrical socket. 5. Insert the connector of antenna into the antenna port of the RM100 UHF RFIDReader Module. 6 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
6. Open the IndyTool. Click Start to scan RFID tags by using the RM100 UHF RFID Reader module. 7 © 2022 Unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of Unitech Electronics Co., Ltd.
FCC 警語置於使用者手冊 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or colocation with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for reevaluating the end product (including the transmitter) and obtaining a separate FCC authorization.