User`s manual

15
Code ID Setting
Each bar code symbology supported by the scanner has a default ID character
defined as below.
CODE ID IDENTIFIER
SYMBOLOGIES Factory ID SYMBOLOGIES ID Factory ID
MSI O CODABAR N
EAN 8 E0
UPC-E E
UPC-A A UK PLESSY P
EAN 13 F
Code 93 L FULL ASCII Code 39 M
Code 11 J
STANDARD Code 39
M
TELEPEN J S25 Code TT
EAN 128 FF INDUSTRIAL 2 OF 5
(Code 2 of 5)
H
Code 128 K China Post Code
(Toshiba Code)
C
Code 32
(Code 39 PARAF)
T INTERLEAVED 2OF 5 T
SET ID - SETTING PROCEDURES
Setting steps:
1. Scan the SET ID bar code for a particular symbology
2. Scan one or two alphanumeric characters from the Full ASCII Table.
Scan the SET ID bar code again.
Example: Define the MSI Code ID = A, Code 93 = G9
MSI:
Step 1: Scan MSI Set ID (Group 5).
Step2: "A"
Step3: Scan MSI Set ID (Group 5).
Code 93:
Step 1: Scan Code 93 Set ID (Group 5).
Step2: "G" from "A" Appendix E. Full ASCII Chart, Scan "9" from "A" Appendix
E. Full ASCII Chart.
Step3: Scan Code 93 Set ID (Group 5).