HT630 Product Reference Guide Unitech Version 1.
HT630 Product Reference Guide NOTICE This unit is equipped with a Li-ion battery pack. Battery power might be low due to storage. Recharge the battery when required. For procedures on how to charge the battery, please refer to 1.5 Quick Start Please note to switch on backup battery and to ensure fully charge the backup battery when you first time to use it. Please refer to the chapter 1Charging portion.
HT630 Product Reference Guide NOTICE .................................................................................................................................................... 2 Chapter 1: Introduction.......................................................................................................................... 4 1.1 Overview .............................................................................................................................. 4 1.2 Support.....................
HT630 Product Reference Guide Chapter 1: Introduction 1.1 Overview Thank you for choosing product from unitech Electronic Co. Ltd. The HT630, Portable Data Collection Terminal, is one of the most versatile handheld computers in the market. It is DOS compatible, capable of running programs, developed under C language. The HT630 has many prebuilt in functions and it is also self-programmable.
HT630 Product Reference Guide 1.4 Technical Specification Physical Characteristics Dimensions: 165mm x 60mm x 35mm Weight: 230g Drop Specification: 1.2M multiple free drop to concrete floor Display: Battery: 128 x 64 pixel; 8 lines, 16 characters per line (small font) or 4 lines, 12 characters (large font). One 3.
HT630 Product Reference Guide 1.5 Quick Start This section is designed to let you quickly get familiar with HT630. If you need detail explanation on some of the functions, please refer to further chapters for detail explanation.
HT630 Product Reference Guide Install Main Battery 1. Remove the battery door from the HT630 by moving the screw from battery cover. 2. Insert the battery into the main battery chamber by putting the head (2 point sticking out) into the locking position first. 3. Reinstalled the battery door and tighten the screw on the battery door again. Charging Before using HT630, main battery and backup battery must be fully charged. The HT630 is equipped with 3.7V 900m.A.H Lithium-Ion battery.
HT630 Product Reference Guide Cradle There are two ways to charge the main battery via the HT630 charging/communication cradle or a quick charging /communication cable. Cradle LED Icons The icon indicates communication. When HT630 is transmitting data with the host computer, LED will flash, showing that the data is transmitting. The icon indicates the charging of the main unit. When the main battery is in charge on the cradle, LED will be shown red; when fully charged, the light will turn to green.
HT630 Product Reference Guide 1.7 Using the Keyboard The keypad of the HT630 consists of 27 rubber keys; the keyboard is configured into three different modes: numeric mode, command mode, and alphabetic mode. All keys except ☉ key make sound (tone) when pressed. Keys of upper four rows have larger size for easier key-pressing to input numbers. [ ☉] To turn on the unit, you need to press ☉ key. To turn off the unit, you will need to press and to hold ☉ key for one second.
HT630 Product Reference Guide 1.8 Triggering Scanner Module The HT630 can be used with a built-in integrated laser scanner module to input data. The built-in decoder reads most barcode labels. Users should keep laser window clean to prevent low reading rate of distorted bar code input signal. 1.
HT630 Product Reference Guide Chapter 2 Power System 2.1 Power System Main Power The terminal is operated by a rechargeable, 3.7V 900mAH rated Li-Ion, battery pack. The main battery should be sufficient for daily operation up to 12 hours. (Base on 5 scan per second) However, since the actual operation may be varied, it is possible to get the shorter result than our standard operation hours.
HT630 Product Reference Guide Remove battery pack z z z z z Remove the main battery as previously described. Important! Once the backup battery is removed from the unit, all data within the unit will be lost, please backup all files before you remove the backup battery. Insert a new battery into the holder. Put the backup battery cap back on. Re-installed the main battery, cold star the new unit. Make sure to back up your data in terminal before making the replacement the lithium back up battery. 2.
HT630 Product Reference Guide It is important to consider the surrounding temperature whenever you are charging the Li-Ion battery pack. The process is the most efficient in the normal room temperature or slightly cooler. It is essential for you to charge battery within the stated range of 32°F to 113°F (0°C to 45°C). Charging battery outside of the specified range could damage batteries and shorten its life cycle.
HT630 Product Reference Guide Chapter 3 Operation The HT630 is set up several operating modes. The system of terminal may operate in various modes for different purposes. The figure below shows the operating flow of the terminal. The following diagram summarized these operating modes to switch between different modes. press and hold down CMD and then press PWR OFF keys press PWR enter program name then press ENTER APPLICATION mode HT630 V1.00 MEM 512KB > press CMD (for two seconds) RUN command 1.
HT630 Product Reference Guide 3.2 User Mode and System Commands There are eight system commands: RUN, TER, COM, DIR, ERA, TYP, CPY, and SET. Each command can be invoked through menu-selection in User mode. User can press [CMD] key for two seconds in Ready mode to enter User mode. User mode prompt (1) RUN (3) COM (5) ERA (7) CPY (2) TER (4) DIR (6) TYP (8) SET Select the corresponding number, 1-8, or press [Å] and [Æ] to highlight a command then hit [ENT] to select a system command.
HT630 Product Reference Guide TYP This command dumps the content of a file on the terminal's LCD. The content of the file will be displayed 128 (16 character x 8 line) characters at a time. Press any key to show the next page or hit [CMD] then [ALPHA] keys to return to User mode prompt. If you try to display a program or binary file, you may only see unintelligible characters. < TYPE FILE > SCAN.DAT CPY This command allows users to make copy of data from a source device to a destination device.
HT630 Product Reference Guide 3.3.2 SCANNER: The system software of terminal decodes all major bar code symbologies including Code 39, Code 128, Codabar, Code 93, I25, EAN, UPC, China Post code, etc. Use the [Æ] key to toggle among selection in each category, then press [ENT] to confirm. SCANNER Enable / disable bar code decoding PEN SCAN KEY When pen scanner is used on the HT630, you can setup whether pressing trigger key to enable pen scanner.
HT630 Product Reference Guide Chapter 4 Built-in Application- FormCaching The system of terminal includes a built-in application, FormCaching. It allows you to create a data entry application from specifying field prompt, type, length, input method and delimiter, etc. without writing program and loading to the terminal. 4.1 Specification of FormCaching DATA FIELD DEFINITION: maximum field number=8 Category Range Description 1 FIELD PROMPT max.
HT630 Product Reference Guide 4.2 How to Create a FormCaching FORMCACHING 1:YES 2:NO OTHER:EXIT You will need to enter Supervisor mode and select “4.FORM” category in order to set the configuration of FormCaching (refer to the HT630 Programming Reference Manual for how to enter the Supervisor mode). After selecting the “4.FORM” in Supervisor mode, the screen will show as above.