Frequency 865 - 928 MHz (US/EU/JP/TW/CN)
Standard
EPC global Class1 Gen2, ISO/IEC
18000-6C
Read Range
1M: When Power is 22dBm
2M: When Power is 27dBm
(Depends on the type and
quantity of
RFID tag and environment)
Weight 106g
Operating Time > 12 hours with 75,000 tag readings
Charge Time 2 hours (via RP902 charging cradle)
3.5 hours (via USB type-C cable)
Bluetooth Bluetooth Class 2, BLE 5.0 (HID / SPP)
Compatibility RP902 with Mfi Versinon:
BT: Android / Windows / iOS (MFi)
USB: Windows
RP902 W/O Mfi Versinon
BT: Android / Windows / iOS (BLE)
USB: Windows
Operating Temp
-10°C to 50 °C
Operating Mode BT SPP Mode
Read Mode Single Read
Power Setting 22 dBm
Beep Setting Low
Vibrate Setting Enable
Auto Power-off 2 min
1. Turn the terminal to its rear side, and push the
battery lock to the right to unlock the battery.
3. Insert the battery into the battery compartment
from the top side and press down, make sure to
leave half of the battery strap outside.
Off Power
off/
Fully charged
――
Red Solid Battery charging Connected with
USB cable
Green Flash RFID tag being
successfully read
RP902 turned on
Blue
Flashing
――
Waiting for BT
connection
Blue Solid
――
BT connection is
successful
LED
LED Status
Status
LED
Communication
LED
LED Indication
Note: During F/W Upgrade, Status LED shows red
solid light & Communication LED shows green solid light.
2. Grab two protrusions on two sides of the battery
cover, and lift upward to remove it.
4. Press down the battery.