Wireless Home Security System User Manual Rev.
Content 1. System Installation Guide 2. User Operation Guide 3. Troubleshooting Guide 4.
WG-110 PC/HTTP Console Configuration Guide Confidential 3
System Architecture 3G WCC-110 3G Mobile 3G IP Camera WiFi Cellular Station WiFi Internet PC Console WG-110 CPE(CM or ATU-R) Ethernet WiFi Zigbee Zigbee-like WR-110 Zigbee-like WLC-110 WSS-110 Zigbee-like WAT-110 3’rd-party Electronic Door Locker WDT-110 WCS-110 WiFi Zigbee 3G WTS-110 WAC-110 WMS-110 Confidential 3’rd-party CO detector WPC-110 3’rd-party Smoke Sensor 4
System Setup Step 1:Power on the Gateway(WG-110) - plug adapter into the wall power socket WG-110 DC 12V IN USB WAN 3G express card LAN Step 2:It takes around 40 sec for Gateway to boot up and get ready, you may check out the LEDs of Power(blue) / Normal(green) to identify Antenna Power LED Alarm 3G WAN Confidential Normal 5
System Setup Step 3:Set up WiFi connection between the PC and Gateway - Power on your PC and enable WiFi(only 802.
System Setup Step 4:Set up PC console - Open the IE browser(6.
System Setup Step 5:Enter the main console of Gateway Confidential 8
System Setup Step 6:Click “System” to change the console login password click here to take effect Confidential click here to abort 9
System Setup Step 7:Click “WAN” to configure Gateway’s WAN interface choose either one to connect to Internet (must be following up with your local ISP OR 3G mobile operator ) Confidential 10
System Setup Step 8:Click “Dynamic IP” to configure Gateway’s WAN interface choose either one as required Confidential 11
System Setup Step 9:Click “Static IP” to configure Gateway’s WAN interface Confidential 12
System Setup Step 10:Click “3GPP” to configure Gateway’s WAN(3G express card) interface user-definable key in the value per your 3G provider Confidential 13
System Setup Step 11:Click “LAN” to configure Gateway’s LAN interface Confidential 14
System Setup Step 12:Click “WLAN” to configure Gateway’s WLAN interface you may change the value as required you may define the key to enable WEP data encryption as required Confidential 15
System Setup Step 13:Click “DDNS” to configure Gateway’s DDNS (Dynamic DNS) information click here to enable DDNS service key in DDNS provider’s domain name key in the value while applying DDNS service (you may attain the account information once done the DDNS service registration) key in the registered domain name Confidential 16
System Setup Step 14:Click “Reboot” to power reboot the Gateway Confidential 17
System Setup Step 15:Click “Reset” to reset all settings to the factory default and power reboot the Gateway Confidential 18
Repeater Setup Step 16:Power on the Wireless Repeater (WR-110) and get connected with Gateway - Plug adapter into the wall socket to power on the Repeater - Push the back side “set” button of Repeater for 5 sec, the indicator will blink blue light twice and turn red light again - Click “Join Repeater” button via the WG-110 console (see next page) to join the repeater - Repeater’s indicator will turn blue light to sync up the access ID with WG-110 - Wait couple seconds or click the “Refresh” button to check
Repeater Setup Step 17:Click “Repeater” to configure repeaters you can join multiple Repeaters thru here Click here to refresh the status click here to clean all binding sensor information the ID has to be matched (Repeater vs.
Repeater Setup Step 18:Click the specific Repeater to configure user-definable alias click here to delete this Repeater connection Confidential 21
Device Binding LED 1. Push Repeater’s button (rear side) once 2. Push Device’s button (rear side or left side nearby logo) once 3. Verify if Device’s LED flashes three times (red color) in sec and meanwhile, verify if Repeater’s LED flashes once (blue color) 4.
Siren Setup Step 19:Click “Siren” to configure sirens alarm mode silent mode Confidential 23
Siren Setup Step 20:Click the specific Siren to configure Confidential 24
Automation Setup Step 21:Click “Automation” to configure controllers Orange means “turned-off” Green means “turned-on” Confidential 25
Automation Setup Step 22:Click the specific Power Controller to configure Confidential 26
Automation Setup Step 23:Click the specific Lock Controller to configure Confidential 27
Sensor Setup Step 24:Click “Sensor” to display all binding sensor information click here to quick refresh all sensor status manually Note: • the console will be auto refreshed in every 20 sec sensor name & id sensor status or current value sensor symbol Confidential 28
Sensor Setup Step 25:Click “PIR Motion Sensor” to configure user-definable alias click here to enable the Partial Arm mode click here to bind the multiple links with the automation-related controllers Confidential 29
Sensor Setup Step 26:Click “Temperature Sensor” to configure current value click here to swap the unit key in the max. threshold value key in the min.
Sensor Setup Step 27:Click “DI Transducer” to configure Confidential 31
Sensor Setup Step 28:Click “Contact Sensor” to configure Confidential 32
Sensor Setup Step 29:Click “Smoke Sensor” to configure Confidential 33
Sensor Setup Step 30:Click “AI Transducer” to configure current value max value of attached sensor coverage min value of attached sensor coverage threshold value click to enable Siren alarm Confidential 34
Arm/Disarm System Confidential 35
Surveillance Setup Step 31:Set up 3rd-party wired IP camera WG-110/DHCP server PC WiFi LAN UTP 1. IP Camera 2. 3. 4. 5.
Surveillance Setup Step 31:Set up 3rd-party wireless IP camera WG-110/DHCP server PC WiFi LAN UTP 1. IP Camera 2. 3. 4. 5.
Surveillance Setup Step 32:Key in IP Camera’s Alias, IP address, and Port mapping to add into IP camera’s RTSP port# IP camera’s HTTP port# click here to add IP camera Gateway’s RTSP port# (must be above 1024) Gateway’s HTTP port# (must be above 1024) Confidential 38
Surveillance Setup Step 33:Reboot Gateway to take effect click here to delete IP camera Confidential 39
Surveillance Setup Step 34:Choose IP camera to monitor using HTTP to display using RTSP to display (to be available soon) Confidential 40
Surveillance Setup Confidential 41
Notification Setup Step 35:Click “Notification” to configure SMS notifications click here to enable SMS notification 886987654321 (country code + mobile num) 886987654322 886987654323 886987654324 up to 4 mobile numbers could be entered Confidential 42
Notification Setup Step 36:Click “Notification” to configure Email notifications click here to enable email notification key in SMTP server’s IP or Domain Name click here to enable SMTP authentication as required key in username/password sales@wss.uisco.com.
System Logout Step 37:Click “Logout” to logout the system click Confidential 44
WG-110 Touch Console Configuration Guide Confidential 45
WCC-110 / Front View Arm/Disarm status indicators/ Boot status Touch screen Battery status indicators Item Description Touch screen 7” 800x480 16:9 WVGA TFT color LCD displays with Touch panel Battery status indicators Dual Color LED(Green, Red) to show the battery status of 1. In charging ( AC power on) - Red LED blinking , 2.Battery discharge- Yellow continue , 3.low battery – Red LED continue on 4.
WCC-110 / Back View # Item Description 1 Connects to an Ethernet 10/100 based network. 2 Ethernet (RJ-45) port External display (VGA) port 3 DC-in jack Connects to an AC adapter. Connects to a display device (e.g. external monitor, LCD projector.
WCC-110 / Side View # Item Description 1 Power button Turn on/off Console Controller 2 USB 2.0/1.1 port Connects to USB devices (e.g. USB camera, USB keyboard). 3 Speaker jack Connects to audio devices (e.g. external speakers).
WCC-110 Setup Power ON : 1. 2.
WCC-110 Setup 1. Key in password The default value is “123” 2.
WCC-110 Setup Click here to logout Touch here to enter into the setup main console Touch here to enter into the Gateway setup screen To be available Confidential 51
WCC-110 Setup Same as PC console Confidential 52
WCC-110 Setup Touch here to enter into the setup main console Touch here to enter into the WCC-110 setup screen Confidential 53
WCC-110 Setup Touch here to enter into the password setup screen Confidential 54
WCC-110 Setup Confidential 55
WCC-110 Setup Touch here to enter into the network setup screen Confidential 56
WCC-110 Setup 1. Key in Gateway’s LAN IP, SSID(if know) & WiFi network key(if have) 3. Click here to activate all settings Confidential 2.
WCC-110 Setup 1. Choose the right SSID that you’re going to get connected with Gateway 2. Key-in the WiFi key if have 3.
WCC-110 Setup Touch here to enter into the setup main console Touch here to enter into the IP Camera setup screen Confidential 59
WCC-110 Setup Key-in IP Camera’s IP address(if know) DHCP IP address release table Click here to renew the table Confidential 60
Content 1. System Installation Guide 2. User Operation Guide 3. Troubleshooting Guide 4.
PC/HTTP Console Confidential 62
PC/HTTP Console Show up the real-time mode once changed Confidential 63
WCC-110 Console Touch here to enter into the Arm/Disarm main console Choose either mode you prefer Confidential 64
WCC-110 Console Touch here to enter into the automation-related main console Confidential 65
WCC-110 Console 2. Choose the IP Cam you want to watch 1.
Content 1. System Installation Guide 2. User Operation Guide 3. Troubleshooting Guide 4.
Troubleshooting Tips Partial Arm mode be disabled Confidential 68
Troubleshooting Tips sensor(vs.
Troubleshooting Tips you can’t enable Partial or Full Arm mode while WCS is in open mode Confidential 70
Troubleshooting Tips disconnected, has to re-do the binding with Repeater (or, you may have to delete it first) Confidential 71
Content 1. System Installation Guide 2. User Operation Guide 3. Troubleshooting Guide 4.
AI/DI Transducer Applications 4-20mA CO Detector AI Transducer NC/NO CO Detector NC Fire Alarm Temperature Sensor DI Transducer DI Transducer 4-20mA GAS Detector NC/NO SMOKE Detector AI Transducer NC/NO GAS Detector AI Transducer DI Transducer Confidential DI Transducer 73
AI/DI Transducer Applications NC/NO_relay-type disaster sensor DI Input 4-20mA AI Input + - AI/DI Transducer Linear-type (data retrievable) disaster sensor Confidential 74
AI/DI Transducer Applications CO sensor DC12v Adapter DC+ DC- , Confidential + - DI Transducer 75
AI/DI Transducer Applications Smoke Detector DC12V Adapter 1 3 4 5 2 6 + - DI Transducer Installing location Bed Bed Bed kitchen room room room Bath room Living room Ceiling mount Top of the ladder from Wall Confidential Gallery 76
AI/DI Transducer Applications 4-20mA + AI Transducer Symbol description: DC POWER SUPPLY:24VDC ~30VDC。 AI Transducer:To transfer 4 ~ 20 mA current to wireless digital datat。 B:Black wire R:Red wire G:Green wire F:Fuse GTF200-FL recommend adopt 0.2A or 0.
AI/DI Transducer Applications 4-20mA current + - AI Transducer To transform the Temperature Sensor signal into wireless control signal by using AI Transducer(4-20mA).
AI/DI Transducer Applications manual button switch Electric Lock + - WLC-110 To transform a conventional Electric Lock signal into wireless control signal by Lock Controller Confidential 79
Product Declaration CAUTION !! - Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Confidential 80
3G WWAN Cards Purchase Inf. • • • • • 3G express card is an option for customer to purchase from the third-party (non-UIS product), it’s highly recommended to choose from UIS’s AVL suppliers. 3G WWAN cards support list of WG-110 Brand Model Number FCCID Number Option NV GE0441 NCMOGE0441 Sierra Wireless Inc. AirCard 880E N7NAC880E The customer should purchase the 3G WWAN cards which shall be FCC approved. 3G WWAN cards must not exceed a maximum ERP of 1.5W for part 22H.
The End Confidential 82