IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of a heater due to improper venting or installation. Call (800) 750-2723 and/or consult a professional
installer if you have any questions.
VENT TERMINATION CLEARANCES:
A. Minimum 4-foot [1.2m] clearance below or
beside any door or window that opens.
B. Minimum 1-foot [0.3m]clearance above
any door or window that opens.
C. Minimum 2-foot [0.6m] clearance
from any adjacent building.
D. Minimum 7-foot [2.1m] clearance from any
grade when adjacent to public walkways.
E. Minimum 2-foot [0.6m] clearance above any
grass, plants, or other combustible materials.
F. Minimum 4-foot [1.2m] clearance from
an forced air intake of any appliance.
G. Minimum 2-foot [0.6m] clearance
below eves or overhang.
H. Minimum 1-foot [0.3m] clearance
horizontally from combustible wall.
NOTICE: This unit shall be installed in such a way that the exhaust gases are directed so they do not jeopardize people,
overheat combustible structures, or enter buildings.
The chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a oor, or ceiling.
Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/
CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment.