Installation Manual

14
4.4.2. Damper Control Module (zoning systems only)
All wiring is run back to the Evolution System Damper Control Module
(SYSTXBB4ZC01). Select a location near the furnace or fan coil where wiring
from the control, each Remote Room Sensor or Smart (Zone) Sensor, each damper
actuator, and the equipment itself can come together easily. The Damper Control
Module is approved for indoor use only and should never be installed with any of
its components exposed to the elements. The Damper Control Module (and zone
dampers) may be installed in any area where the temperature remains between --4_F
to 158_F(--20_Cto70_C), and there is no condensation. The cover must be
installed to prevent damage from other sources. Do not locate where it will be
accessible to children. It may be mounted in either vertical or horizontal position.
Remember that wiring access is likely the most important consideration.
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
To prevent possible damage to the Damper Control Module,
DO NOT mount on plenum, ductwork, or flush against
furnace or fan coil.
CAUTION
!
4.5. Mounting
First become familiar with all plastic assembly pieces shown on the following page.
The Evolution Connex Control will snap together with the standard backplate
supplied with the wall control. Attach backplate using only a small hole in the wall
allowing a four wire connection to pass through. Mount the front assembly to the