Operating instructions
The Technical Stuff 
__________________________________________________________ 
- 38 - 
Ground Isolation Jumpers 
Each of the eight balanced connectors (the analog and AES digital I/O) can individually isolate pin 1 
from ground if desired via an internal jumper block. The table below indicates which internal jumper is 
used for each balanced connector. Pin 1 is tied to ground for the connector when the indicated pair of 
pins is jumpered. The 2192 is shipped from the factory with pin 1 connected to ground on all eight of 
these connectors. 
Connector 
Jumper 
Analog input left 
JP1 
Analog input right 
JP4 
Analog output left 
JP5 
Analog output left 
JP6 
AES input A 
JP9 
AES output B 
JP10 
AES input A 
JP11 
AES output B 
JP12 
 (Note: Pin 1 is tied to ground when a jumper is across the pair of pins) 
Fuse 
There is no user accessible fuse for the 2192. It contains an internal power supply circuit board with 
its own fuse. (Fuse type: T 2A 250V.) 
Voltage Select 
The 2192 contains a universal auto-sensing, filtered, multi-stage regulated power supply which 
supports 100-240VAC and 50-60Hz power for trouble-free operation worldwide. No switch setting is 
required when changing from 115 to 230 volt use or vice versa. 
 Changes to internal jumpers should only be made by qualified personnel. Be sure to 
disconnect AC power before opening the unit! 