Operating instructions
Specifications 
_______________________________________________________________________ 
- 49 - 
Dynamic range (measured using       118dB (A-weighted), 115dB (unweighted) 
-38dBu = -60dBFS input at 1kHz)       (see page 38) 
Frequency response (relative to 1kHz)      +/- 0.02dB, 10Hz to 20kHz @ Fs=44.1kHz 
+/- 0.04dB, 10Hz to 40kHz @ Fs=96kHz 
Phase response          <0.1°, 10Hz to 1kHz, -1.0° at 20kHz 
Residual noise (200Hz-20kHz)        < -145dBFS (-123dBu) 
Total Harmonic Distortion + Noise (measured at 1kHz)  -110dB, with +4dBu input 
-114dB, with -10dBu input 
D/A 
Dynamic range (measured with        122dB (A-weighted), 119dB (unweighted) 
-60dBFS = -38dBu output at 1kHz)      (see page 38) 
Frequency response (relative to 1kHz)      +/- 0.03dB, 10Hz to 20kHz @ Fs=44.1kHz 
+/- 0.04dB, 10Hz to 20kHz @ Fs=96kHz 
Phase response          <0.5°, 10Hz to 1kHz, -10° at 20kHz 
Residual noise (200Hz-20kHz)        < -145dBFS (-123dBu) 
Total Harmonic Distortion +N (measured at 1kHz)   -98dB, with +4dBu output 
-103dB, with -10dBu output 
Physical: 
AC Line Connector  IEC 3-pin power (safety ground 
ties to chassis at entry point) 
Voltage             100-240VAC, 50-60Hz, auto-sensing 
Fuse               Internal, type T 2A 250V 
Power Consumption          40 Watts 
Thermal             0° C to 50° C 
Dimensions            1.75" H x 19" W x 12.5" D 
(1RU standard 19" rack-mount chassis) 
Weight           15 lbs. (with carton)       
~ All specifications are subject to change without notice ~ 