Manual

13
LINE
OUTPUT
LINE
INPUT
MIC
INPUT
LINE
OUTPUT
LINE
INPUT
1176 SA
POWER IN:
115V ~ 50/60Hz 400ma
230V ~ 50/60Hz 200ma
FUSE RATING:
T 400ma L 115V~
T 200ma L 230V~
REPLACE FUSE WITH SAME
RATING AND TYPE ONLY!
UNIVERSAL AUDIO, INC SANTA CRUZ, CALIF. USA
CAUTION / AVIS
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
!
CAUTION: TO REDUCE THE RISK OF FIRE OR
ELECTRICAL SHOCK DO NOT EXPOSE THIS
PRODUCT TO RAIN OR MOISTURE
ATTENTION: POUR REDUIRE LE RISQUE DU FEU
OU DE CHOC ELECTRIQUE N'EXPOSEZ PAS CE
PRODUIT A LA PLUIE OU A L'CHUMIDITE'
CE
6176 COMPRESSOR 6176 PREAMPLIFIER
600W
15KW
Figure 4: 6176 Rear Panel
Input/Output
Standard XLR input and output connectors are provided on the rear panel. Pin 2 is wired
positive (hot) on the LINE and MIC INPUTS. Pin 2 is positive on the 610B LINE
OUTPUT when the front panel Polarity toggle switch is down (IN ). Pin 3 is positive
on the 610B LINE OUTPUT when the front panel Polarity switch is up (OUT ).
1176LN Input Loading
The 1176LN Input Loading switch is located to the right of the LINE INPUT XLR.
When the button is pushed in, the input impedance will be 600 ohms, typical of older
vintage gear. When the button is out, the impedance will be 15K ohms. In some situations
you may perceive a “brighter” tone by using the 15K ohm position.
AC Power
The 6176 uses a standard, detachable IEC power cable.
Fuse/Mains
The AC power fuse is located in the AC power connector block. Remove the power cord
before checking or changing the fuse.
A 400 mA time delay (slow blow) fuse is required for operation at 115 V.
A 200 mA time delay (slow blow) fuse is required for operation at 230 V.
Voltage Select
The 6176 can operate at 115 V or 230 V. To change the mode, wait 5 minutes after power
down, unplug the AC power cord from the rear chassis. Remove the top cover. As
shown below, there is a connector that can be plugged in to one location or another
location to configure the unit for 115V or 230V operation. This figure shows the unit
configured for 230V operation. The connector can be identified by it’s wire colors;
Black, Blue, White, Orange. This connector should be plugged into location H8 for 230V
operation and location H6 for 115V operation. The connector is part of the wiring that
comes from the power transformer located at rear center of the 6176. When changing
operating voltage, fuse value must be changed as well. Make sure the 6176 is properly
set for the voltage in your area before applying AC power to unit!