UAD Powered Plug-Ins Manual - 36 - Chapter 2: UAD Installation
To confirm proper UAD installation and operation:
1. 
Launch the UAD Meter & Control Panel application (see page 62).
2. Open the System Information panel (see page 64).
3. When the UAD device is displayed in the Hardware area and its status is 
“OK” then the UAD driver is communicating with the UAD device and the 
system is operating properly. Done!
UAD-2 LED The UAD-2 has an LED indicator. This LED provides certain indications about 
the operational state of the UAD-2. The location of the LED depends on the 
UAD-2 product. On UAD-2 PCIe cards, the LED is on the mounting bracket of 
the card. On the SOLO/Laptop, the LED is next to the UA logo on the black 
housing. On UAD-2 Satellite, the LED is on the rear panel.
Alternating red and green
When the LED alternates between solid red and solid green, the device is 
powered up properly but the UAD driver is not yet loaded or communicating 
with the device. This is the expected state if the device is installed but the soft-
ware is not yet installed, or when booting the system and the UAD driver is not 
yet loaded.
Solid green
When the LED is solid green, the UAD driver is loaded and properly commu-
nicating with the device. This is the normal state when using UAD Powered 
Plug-Ins.
Solid red or other blinking patterns
When the LED is producing any pattern other than the two conditions above, 
there is a problem with communication between the driver and the device. Try 
a cold reboot (complete power down) and/or reinstalling the UAD software 