User's Manual

UniLink UL-800/801 FANS
SCN 30.X
Operator’s Manual
100 23-20-06.02
December 2011
The IN time that is recorded for the IN event is the last time the brake
was set prior to the door opening, or the time that the door opens if
the brake was not set. The time for all other OOOI events is the time
that the UniLink detected the last state change required for the
transition to occur.
Ground Delay (Optional)
Menu Navigation: UNILINK MENU > MAINTENANCE > SENSOR STATUS
To determine OOOI status, navigate to the SENSORS 1/2 page.
A GROUND DELAY ADVISORY occurs when the configured time on
the Ground Delay Timer expires after doors closed /brakes released
(OUT event) but before Weight-Off-Wheels/Takeoff (OFF event).
The GROUND DELAY ADVISORY annunciation will display at LSK
[5L].
Pressing LSK [5L] will display the DELAY page. The crew can send a
ground delay report by following the procedure listed in the DELAY
section of this manual.