User guide

29
In the example below, when the highlighted controller is pressed the
TheaterControls1A-Table device will turn on to 60% and the TheaterMain1 and
TheaterMain2 devices will turn off. All devices are set to use a 2 second ramp rate.
There are a couple of other options available when adjusting scenes:
Apply Changes To All Devices. This option will merge all Responder sliders to
one slider to make bulk changes easier. For example, if you want all responders
in a scene to turn on to 50%, simply check the Apply Changes To All Devices
option and drag the single slider to 50%.
Copy Scene Attributes From... As noted above, the ISY itself is also a
controller of every scene. If a controller within a scene should use the same
values as the ISY uses when controlling a scene, simply click this button to copy
the values from the ISY over to the currently selected Controller.
NOTE: Once programmed, scenes operate independently of the ISY – all programming
is saved to the INSTEON devices. If the ISY is turned off or is offline for some reason,
programmed Scenes will still operate as expected.
NOTE: It’s important that all links between devices are created from within the ISY.
Avoid creating links manually between devices or using other software packages –
unexpected results will occur.