User guide

Triggers
Thermostat Heat/Cool
Call Triggers
Off, Heat, Cool
Program Triggers Becomes True, Running True, Becomes False, Running False,
Enabled, Disabled
Weather Triggers All WeatherBug parameters
Energy Monitor
Triggers
Utilization, Total Utilization, Polarized Utilization, Voltage,
Current
IR Triggers Press, Hold, Release, Double
X10 Triggers On, Off, Dim, Bright
ELK Triggers Disconnected, Connected, Disarmed, Armed Away, Armed
Stay, Armed Stay Instant, Armed Night Instant, Armed Vacation
FLEX Triggers True, False
NTP Triggers Date/Time
The ISY Insteon Plug-in continuously listens for event notifications from the ISY. The
incoming notifications are queued and processed in the order they are received. Once
processed, the notifications are translated into HomeSeer triggers. HomeSeer will then
check the trigger string and activate any matching trigger. Note that some of the above
triggers require optional ISY modules to be installed.
Conditions
The ISY Insteon Plug-in supports HomeSeer's ConditionUI and allows ISY events and device
status to be combined in complex logical conditions.
Actions
The ISY Insteon Plug-in installs actions into HomeSeer for the various commands that can be
executed by and through the ISY.
Action Name Parameter Action
ISY Program Program ID Run If, Run Then, Run Else, Enable, Disable,
Run at Reboot, Don't run at Reboot, Stop
ISY Dimmer Device or Scene On, Off, Fast On, Fast Off, Dim, Bright
ISY Relay Device On, Off
ISY Scene Scene ID On, Off, Fast On, Fast Off, Dim, Bright
ISY Thermostat
Control
Device Set Mode, Set Fan Mode, Increment Set Point,
Decrement Set Point
ISY Thermostat Set Device Set Point, Heat Set Point, Cool Set Point,
Humidity