NevoConnect NC-50 is a Z-Wave enabled base station that allows non-line of sight control of infrared and serial devices along with sensing of a device’s power state via video or voltage sensors. NevoConnect NC-50 Requirements You will need a NevoConnect NC-50 in each room or equipment closet containing devices to be controlled. You must configure each Nevo Controller to send commands via NevoConnect NC-50. See the NevoStudio Pro Design Guide for more information.
NevoConnect NC-50 Features 4 IR Blaster LEDs and a Front Panel Activity LED (all behind the plastic) 3.
Wireless IR Control In a wireless setup, NevoConnect NC-50 can simply be set so that the IR blaster on the front is within the IR range of the devices to be controlled: IR receiver on device 180° 30° 15.24 m 15.24 m IR receiver on device Wired IR Control NevoConnect NC-50 can be used in a wired configuration for installations where the device needs a direct connection.
To set this up: 1. Connect any combination of up to 6 IR Emitters (one for each device to be controlled, sold separately), Nevo Serial Modules (sold separately) or Nevo sensing devices (sold separately) to the programmable ports on NevoConnect NC-50’s rear panel. Installer Tip: Serial and sensing devices must be plugged into the port that was assigned to them as part of the device setup in NevoStudio Pro. 2.
Z-Wave Terminology The following table describes the terms used in Nevo wizards and their relationship with terms used in the ZWave standard:. Nevo Text Z-Wave Action Notes/How it’s used Add Inclusion Also used to initiate Controller Replication from a Primary. Remove a node from the current or another network. Also referred to as “Change Primary”, initiated from the Primary Controller to pass on the Primary role to another Controller.
Add/Remove NevoConnect NC-50 The Z-Wave network is managed by the Primary Controller. There are two steps to add NevoConnect NC50 to a network, regardless of what manufacturer device is serving as the Primary Controller: 1. Add/Initiate Inclusion on the Primary Controller (on NevoQ50, press the Add button). 2. Press the Program button on the rear panel of NevoConnect NC-50 for approximately 1/2 second.
2. Press and hold the program button on NevoConnect NC-50 for 10 seconds (until you see the Power LED blink twice). 3. Press Program on the Controller that is to be the new Primary Controller. 4. When the process is complete, the Power LED will blink twice then remain on. The duration of the blinks indicates if the process was successful, just as in the Add/Remove NevoConnect NC-50 process. You can confirm that Nevo is now the Primary Controller by selecting the Z-Wave option from the Settings menu.
If you need help... • • • • Refer to the NevoStudio Pro Design Guide Refer to the online knowledge base at www.mynevo.com Contact your distributor Contact Technical Support NOTICE: Nevo, Nevo Q50 , NevoStudio, NevoStudio Pro and NevoConnect are registered trademarks or trademarks of Universal Electronics Inc., in the United States and/or other countries. Other product and company names may be trademarks of their respective companies.
equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the user’s authority to operate this equipment. FCC ID: MG310370 IC ID: 2575A-URC1037 . Copyright 2007 Universal Electronics Inc.