Calibration ('K') Factor
The 'K' Factor is a ratio of litres dispensed per revolution of the meter.
Below is the method of calibration, including how to calculate the new 'K'
Factor and how to enter it in the C4000 memory.
(See also Encoder (see page 54) for more information on the
encoder/pulser)
Calibration
To calibrate the dispenser/pump, dispense fuel into a certified measuring
container, and compare the display value with the amount dispensed.
Example:
Display shows 10.00
True volume 20.00
To calculate the correct 'K' Factor from the information above; firstly record
the existing 'K' Factor.
2 Factor K'' Existing
10.00
20.00
Factor K'' Existing
Amount Dispensed
Factor K'' Factor K''
AmountDisplayed
Exis ti ngNew