Specifications
Set-up Modes
No Flow Cut-Off Timer
Compac Industries Ltd.
Page 25
www.compac.co.nz
No Flow Cut-Off Timer
Under normal conditions to end a transaction on a C4000 controlled
pump/dispenser, there are three possibilities:
Returning the nozzle to its holder.
Reaching the preset amount entered.
Cut out on the 'No flow cut-off timer'.
The No Flow Cut-off Timer sets the amount of time the dispenser/pump will
allow a sale to continue when no flow is detected. This timer applies at both
the beginning fill before filling commences and at the end of the fill after
flow has stopped. The No Flow Cut-off Timer is terminated if the nozzle is
returned to its holster.
The range available is between 1 & 256 seconds. The default setting is
'n0000' (256 seconds).
Setting the No Flow Cut-Off Timer
Refer to C4000 Set-Up K Factor Switch Settings (see page 21).While
setting this value the price display will indicate „n‟ and the volume display
will indicate „nXXXX‟.