Specifications
Display (Litres) Resolution 
Set-up Modes 
Compac Industries Ltd. 
Page 26 
www.compac.co.nz 
Display (Litres) Resolution 
For standard dispenser/pumps, high flow dispenser/pumps & bulk metering, 
different resolutions are often required: 
Display 
Resolution 
Sr setting 
on k factor 
switch 
Litres Display 
resolution 
Max 
presetable or 
fill amount 
Standard (default) 
0.000 
0.00 
970 L 
Hi-Flow 
0.00 
0.00 
9700 L 
Bulk-metering 
0.0 
00000.0 
0 
000000 
000000[0] 
[0] is not 
displayed 
 As well as displaying the decimal point, a full colon will show 
on the display after 'power on', until the first transaction is started (i.e. the 
display shows „:0.0‟ until the first new transaction begins). 
The display resolution does not affect the price display, which will always 
display to a resolution of 0.01 dollars. 
Setting the Display Resolution 
Refer to C4000 Set-Up K Factor Switch Settings (see page 21) 
Step 
ACTION 
RESULT 
1 
Ensure that the nozzles are 
hung up 
Dispenser in idle state 
2 
Press and release the „K‟ 
Factor switch continuously 
until the Litres resolution is 
displayed 
The price display indicates „Sr‟ 
and the Litres Resolution is 
displayed as “0.00” (standard 
resolution on 5-digit display) 
3 
Press and hold the „K‟ factor 
switch. 
The decimal point will begin to 
move. 
4 
When the resolution 
(decimal point) is correct, 
release the „K‟ Factor 
switch. 
 The C4000 will 
reset itself if the „K‟ factor 
switch is left for more than 10 
seconds. 