Specifications
Set-up Modes
Solenoid Delay
Compac Industries Ltd.
Page 27
www.compac.co.nz
Solenoid Delay
The Solenoid Delay was installed in the program to enable the "delay"
between the submersible pump operating and the dispenser solenoids
operating to be controlled on initial start-up. This setting should only be set
on dispensers.
This setting should never be set more than 4-6 seconds. Its main purpose
is to allow the leak detector on the submersible pump to carry out its leak
test.
The default setting is 'd0000‟ (i.e., no delay). All dispensers with a self-
contained pump should be left at the default setting.
Setting the Solenoid Delay
Refer to C4000 Set-Up K Factor Switch Settings (see page 21). While
setting this value, the price display will indicate „Sd‟ and the volume display
will indicate „dXXXX‟ where X equals one second.