Temperature Calibration
Only available for LPG and Bulk-meter modes and only if the Temperature
Compensation PCB is installed and temperature compensation configured
as detailed in Section 0
To set the temperature, place the probe in product of a known temperature.
Allow 10 minutes for the probe temperature to stabilise, then adjust the
temperature setting in the register 'XXX.X' to the known temperature value.
To check operation of the probe, press the 'K' factor switch to observe E in
the Price display and „XXX.X' in the volume display. Allow the display to
return to normal. Warm the probe and recheck the K-Factor switch
temperature setting. The new temperature should be displayed.
The temperature is not updated while it is being displayed.
Setting the Temperature
Refer to K Factor Switch Settings (see page 21) While setting the
temperature, the price display shows E and the volume display shows
'XX.X'. The temperature is displayed in degrees Celsius.
ACV Valve Flow Rate
This is only available in Bulk Meter mode where the ACV Valve has
'Compac Designed' controls. The Configuration code must be set-up for
“Compac flow modulation” (4th digit set to 2. Refer to Configuration Code
(see page 16) )
Setting ACV Valve Flowrate
Refer to K Factor Switch Settings (see page 21) While setting the ACV
Valve flowrate, the price display shows 'FLO' and the volume display shows
'rXXXX'. The desired flowrate for the system must be entered in litres per
minute.
L-Cut
This is only available in Bulk-meter mode.
This value is similar to the preset cut-off used in a standard dispenser. Prior
to the delivery reaching its preset amount, the solenoids are switched to
give a low flowrate. The “L-Cut” sets the amount (in litres), prior to the
preset amount being attained, at which the solenoids will switch to a low
flow rate.
Setting L-Cut
Refer to K Factor Switch Settings (see page 21) While setting the “L-Cut”,
the price display shows 'LCUT' and the volume display shows 'LXXXX'.
H-Cut
This is only available in Bulk Meter mode.