Specifications
Set-up Modes 
Parameter Switch 
Compac Industries Ltd. 
Page 33 
www.compac.co.nz 
Parameter Switch 
Refer to Figure 1 Main Features C4000 (see page 12) to find the location of 
the parameter switch. 
The Parameter switch has several functions including: 
  Identifying the software programme version number, 'P XX' 
  Setting the dispenser/pump price, 'Pr' or 'P' 
  Setting the  product density, 'dEn' (Bulkmeter  Registers and LPG with 
compensation but without a densometer only) 
  Setting the pump/dispenser number, 'Pn' 
  Displaying End of Sale indications 
  Setting the dispenser sequencing rate, 'SE9' (CNG only) 
  Validating  and  invalidating  cards/pins/keys,  'Y'  or  'n'  (Comcard, 
Compin, or CWIDKey pumps/dispensers only) 
  Setting  the  card  access  code,  'A'  (Comcard  or  CWIDKey 
pumps/dispensers only) 
  Conducting Display Segment Test 
 Parameter Switch Settings - all must be set, but the order of 
the set-up is not critical. 
Program Version Number 
To determine program version number, hang up the nozzle, then push the 
parameter switch once. The system enters a diagnostic mode whereby it 
displays the program type data and performs a display segment test. When 
showing program data, the display panel shows 'PXX' where 'XX' is the 
program version number. 