Specifications

Parameter Switch
Set-up Modes
Compac Industries Ltd.
Page 34
www.compac.co.nz
Setting the Price per Litre
The C4000 processor board can be set for five hose configurations:
1. Single (e.g. one C4000 controls one hose)
2. Dual (e.g. one C4000 controls two hoses)
3. Quad (e.g. one C4000 controls four hoses but only two (one per side)
can operate at any time)
4. True Quad (e.g. one C4000 controls four hoses which can all operate
at once)
5. Six (e.g. one C4000 controls six hoses but only two can operate at
once)
The following charts are to be used to set the price.
Setting Price for a Single or Dual Hose Configuration
Step
RESULT
1
Dispenser in idle state
2
The Price for side „A‟ is displayed
as „PX.XXX‟ and „Pr‟ is displayed
on the price display.
3
A digit, of the displayed „Price per
litre‟, will begin to increment.
4
5
The C4000 will
reset itself if the Parameter switch
is left for more than 60 seconds.
Continue for Dual hose units
6
The „Price per litre‟ for side “B” is
displayed as „bX.XXX‟ and „Pr” is
displayed on the price display.
7
If a Compac Central Controller, EFTPEC, Task forecourt controller, or
Compac Commander is used, the price must be set to zero (0) at the
pump/dispenser. The price can then be set at the Controller. This applies
to all configuration display options.
The dispenser/pump will stop when the dollar amount reaches: $999.99
(high-flow $9999.9) or the litre amount reaches 999.99l (high-flow 9999.9l)
whichever occurs first.
The dispenser will not allow the price/litre to be altered during a delivery
When the price/litre is altered, the dispenser will display the new price/litre
for at least 5 seconds before allowing a new transaction to begin.