Specifications
Displays: Litres only, Retail, Multi-price & Preset
Electrical Wiring C4000
Compac Industries Ltd.
Page 56
www.compac.co.nz
Totalisers
Electromechanical Totalisers
Only approved Compac totalisers are to be used. Some totalisers have a
+ve and a -ve terminal.
Electronic Totals
As well as having electromechanical totalisers for litres dispensed from the
pump, each C4000 stores in its memory a five-digit litres total of fuel
dispensed from each hose. Both these totals are non-resettable.
These totals can be displayed by pressing the CANCEL or FILL buttons on
the preset keypad, of the meter/hose in question, five times in quick
succession.
The totals will then appear on the pump displays, on the LITRES and
DOLLARS display, for ten seconds before the display resets.
In the absence of a preset keypad, remove the nozzle from the nozzle
holder. Hold the nozzle switch down for at least three seconds and then tap
it down five times in quick succession. The totals will appear as described
above.