Specifications

High Current Triac Option
Indicator LEDs
Compac Industries Ltd.
Page 66
www.compac.co.nz
D17
D16
D15
D14
D13
D12
D11
D10
D9
D8
D18
Output LEDs
Diagnostic LED
C4000 microProcessor PCB
Figure 6. Location of Output & Diagnostic LEDs
Output LEDs
The ten Output LEDs (refer Figure 6) indicate which triac outputs are being
switched on. D8-D17 corresponds to the output triacs T1-T10 (refer Figure
7).
Diagnostic LED
The Diagnostic LED Figure 6) flashes in three different states when the
processor is working properly:
When the pump is idle and in 'stand-alone' mode, the LED flashes
slowly and consistently.
When the pump is idle and communicating with a controller the LED
flashes slowly but erratically.
When the nozzle is lifted from its holster, the LED flashes quickly.