Specifications
Fault Finding 
Error Codes 
Compac Industries Ltd. 
Page 69 
www.compac.co.nz 
Error Codes 
Error Code 
Fault 
Action 
Err 3 
No price set. 
Set a price at the pump or at the controller. 
Err 4 
CWID offline. 
Check connections. 
Change CWID PCB. 
Err 7 
Excess flow. 
Check for air. 
Err 8 
Excess reverse rotation of encoder. 
Check product is not flowing back into the tank 
once the delivery has finished. 
Err 9 
Faulty encoder or disconnected encoder. 
Check encoder circuit. 
Err 10 
Configuration Lost 
Reconfigure C4000 
Err 11 
Invalid access code 
(Comcard or CWIDKey Basic systems only). 
Enter valid access code. 
Err 12 
C4000 memory failure. 
Change memory E2prom 'chip'. 
Err 13 
Temperature/Pressure Interface unplugged. 
Reconnect interface board or replace. 
Err 14 
Temperature Probe disconnected. 
Reconnect temperature probe or replace. 
Err 15 
Pressure Probe disconnected (LPG only). 
Reconnect pressure probe or replace. 
For Error 7 (LPG) also occurs if flow rate exceeds 100 litres/min. 
For Error 8 excess reverse rotation means the encoder has turned 
backwards more than 3/4 of one turn during a delivery, or within two 
seconds of the end of a delivery. This only occurs if the non-return valves 
installed on site are faulty. 