Error Messages
On Pump
LCD
Display
On PIN Pad Dot
Matrix Display (if
Connected)
Explanation
REPAS
Pass Again
Card not read properly, try re-swiping. In addition, C4000 may be configured for
the wrong card reader track, or the card or card reader could be faulty.
HOLD
System not ready
Pump no longer communicating with Central Controller.
:0.0
The full-colon on the display indicates that the processor supply has been OFF
and back ON since the last transaction.
_ _ _ _ _
Restricted Fuel
Card not validated for the pump/dispenser fuel grade set.
_ _ _ _ _
Wrong System
Incorrect card used or the controller has the incorrect access code or ISO number
set. Or requires setting for a particular Card Type.
_ _ _ _ _
Expired Card
Card expiry date is earlier than controller date
_ _ _ _ _
Bad Card
Algorithm check sum on cards is invalid
_ _ _ _ _
Wrong Pin
An incorrect or invalid pin has been entered.
_ _ _ _ _
Wrong Network
The network encoded on the card is invalidated in the controller.
RAnGE
Temperature probe out of range. (Only displayed when temperature setting
selected on K Factor Switch). Probe either faulty or not connected.
Low Battery
Fault on Secure PIN pad Processor PCB- replace complete PIN pad.
Memory Error
Fault on Secure PIN pad processor PCB replace complete PIN pad.
AIr
(Flashing)
The air cut-out switch has operated.
GAS
(flashing)
LPG ONLY. Flow rate fell to between 0 and 6 litres/min for more than 6 seconds.
Indicates creepage due to presence of vapour.