User's Manual
CO2ZB1ZigbeeCO2Sensor
InstallationInstructionsandUserManual
1. Specifications
Frequency: 2.4GHz(IEEE802.15.4)
OperatingTemperature: 14°‐122°F(‐10°‐50°C)
OperatingHumidity: 10%‐90%non‐condensing
CO2SensingRange: 400ppm–5000ppm
CO2SensingAccuracy: ±75ppm+5%MV
Battery: 4xAAAlkalineBattery
BatteryLife: 2Years(withdefaultsetting)
Compatibility: Zigbee,
WWAH(WorkswithAllHubs)
2. PackageContents
1xSensor
2xScrews&WallAnchor
4xAAAlkalineBattery(uninstalled )
2xBackMounting2‐SidedAdhesiveTape
1xManual
3. ComponentIdentification
4. ZigbeeEnrollment:
ThisCO2Sensorneedstobepairedbeforeinstallation.
1. Insert4batteriestothebatterycompartment
2. TheLEDwillblinkthreetimesinambercolorevery2‐3secondswhile
scanningthenetwork.
3. Ifnetworksuccessfullyjoined,theLEDwillbelitfor1secondinambercolor
followedbyashortblinkingreencolor.
4. Ifnetworkisnotfoundafter1minute,thesensorwillgointosleepmode,
theLEDwillblinkinambercolorevery1minute.Youneedtoresetthe
sensortotriggerapairingprocess,andthensensorwillrepeat
stepsfrom2
to4.
Toresetthesensor:
1. Removethebatteryfor10seconds
2. Pressandholddownthetamperswitchwhilere‐insertthebattery
3. Releasethetemperswitchwithin3secondsafterinsertthebattery
Note:MACaddressoftheSensorcanbefound
ontheQRcodebyscanningit
withyourmobilephone.
5. Mounting
MountingbyScrew
Pressthecasereleasebuttontoseparatethefrontandwallanchorcase.
Thebackcasegivesaccesstoboththeflushmou ntandcorn ermount
screwknockouts.Drillthroughtheappropriateknockoutsandusethe
includedscrewstomountinthedesiredmounting
location.
Itisrecommendedtoensurethereisatightsealaroundtheknockoutsto
preventbugsfromenteringthesensorandcausingfalsealarms.
Replacethefrontsensorcovertosnapshutandscrewinthesensorcase
screwsonthetopandbottomofthewallanchor
case.
MountingbyAdhesiveTap
Pressthecasereleasebuttontoseparatethefrontsensorcaseandwall
anchor.
Insertthebatteryintothebatterycomp artment.
Putbackthewallanchorcasewithfrontsensorcase.
Placeonesideadhesivetapeoverthe
wallanchorcase,thesidethatwill
facethewall.
Peelofftheothersideofadhesivetape.
Placethesensoronthewall.
6. Operation
TheCO2sensorrequires45secondstowarmupforsignalstabilizingwhen
performingstartuporreset.Duringthewarmupperiod,theLEDwillblinkslowly
inamber.Duringnormaloperation,theLEDwillblinkevery5minutesingreen
colortoindicatethesensorisworkingproperly.However,there
arenoLED
indicationswhenmotionisdetected.Thisisdonetomaximizebatterylife.
Furthermore,whenmotionisdetectedandasignalistransmittedtothepanel,
thesensorwillnottransmitagainforaperiodofthreeminutes.