- Universal printer MAINTENANCE OWNER'S MANUAL

33
7- Retighten the Brass Tipped Set Screw to lock the Index Ring in position. This screw must be tight to
prevent the Index Ring from rotating under spring tension.
6- Rotate the Index Ring in a clockwise direction until it stops turning. Next, turn the Index Ring in the
counterclockwise direction as necessary until the Brass Tip Set Screw is pointing directly at the
Transfer Roll Axle as shown in Figure 63.
5- Using a 1/8" hex wrench, loosen the Brass Tipped Set Screw
located in the side of the Index Ring until the Index Ring
rotates freely.
MAINTENANCE
Important Note: The Print Drum Axle is machined with
thread relief as shown in Figure 40 so the tip of the set
screw will not damage the threads. To completely remove
the Index Ring from the Axle, the Brass Tip Set Screw must
be loosened at least 2 full turns to prevent damage to the
threads.
FIGURE 61
FIGURE 63
FIGURE 62
.04
BRASS TIP
SET SCREW
PRINT DRUM AXLE
RECESS AREA
LEFT HAND
CONFIGURATION
RIGHT HAND
CONFIGURATION
INDEX RING
BRASS TIP SET SCREW
TRANSFER
ROLL AXLE
INDEX PLUNGER
INDEX RING PIN