Specifications
BASIC SYSTEM MAINTENANCE
Section 4-4
Beam Window
• The Beam Window is where the laser
beam enters into the engraving area. It is
located in the upper left hand corner,
towards the rear of the engraving area.
• It is only necessary to clean the front side
of the Beam Window. The backside is in a
sealed environment and should not get
contaminated.
• DO NOT remove the Beam Window for
inspection or cleaning. Inspect the optic in
place and clean if necessary.
1. Beam Window
The Motion System
• Using a vacuum cleaner, vacuum all loose dirt and debris from the inside of the device.
• Outside the device, dampen a paper towel, cotton cloth, or terry cloth with the soap solution,
alcohol, or acetone and wipe down the Z-axis Engraving Table. Be careful not to spill any chemical
on any painted surface.
• Locate the four X-axis Bearings (1).
Dampen a cotton swab with either the
soap solution or alcohol. Place the
dampened swab against the bearing (2),
grasp the focus carriage (3), slide the
focus carriage left and right, allowing the
bearing to roll in the v-groove (4). Pay
attention to the part of the bearing that
contacts the v-groove both on the top and
the bottom side of the bearing. Also, use
the dampened swab to clean the v-groove
(4). Make sure you clean all 4 bearings.
• Locate the left and right side Y-axis Rails
and their respective v-grooves as the
arrows in the photos indicate. This is
where the Y-axis Bearings (not visible)
make contact with the rail. Dampen a
cotton swab or cotton cloth with either the
soap solution or alcohol, and clean the v-
groove. Gently slide the X-axis Arm
towards the front or rear of the device so
that you have access to the entire length of
the v-groove.