Specifications
BASIC SYSTEM MAINTENANCE
Section 4-6
Cooling Fan Filters
1. Side cooling fan filter (inside cover)
2. Rear cooling fan filter (inside cover)
3. Rear cover mounting screws
4. Lift the cover straight up and off
The side (#1) and rear (#2) cooling fan filters are located inside the Rear Cover. To access them, remove
the two mounting screws (#3) underneath the rear of the system. Lift the cover straight up and off.
Locate the filters on the inside of the cover (not shown). Remove the plastic retainer and the filter media.
Rinse the filter media with soap and water. Allow them to air dry off or dry them off before re-installing.
Maintenance Schedule
Since the maintenance requirements of the VersaLASER is dependent on the type of material being run,
the quantity of material being removed, the hours of operation, and the quality of the exhaust blower, it
must be user defined.
However, as a starting point, we recommend the following schedule:
• As necessary
Engraving table
Main enclosure
User door
• Every 8 hours of engraving
Clean X-axis bearings and bearing tracks
Check Beam window, #2 Mirror, #3 Mirror, and Focus Lens for debris. Clean ONLY if dirty.
• Every month
Clean side and rear cooling fan filters
• Every 6 months
Exhaust plenum
If you are noticing a considerable buildup of debris on the optics and the motion system, clean
the system at more frequent intervals. If your system has remained relatively clean, you can
extend your cleaning intervals. Keep in mind that a clean machine is a better performing machine
and can extend the life of the parts as well as reduce the possibility of down time. If you have any